/
Injection Balance

Injection Balance

Search the Qbyte Metrix Wiki
 

Back to Monthly Data Entry and Balance Screens

 

Overview

The Injection Facility Balance screen is used to enter data associated with Injection Facilities, some of which is required for Volumetric and SAF/OAF submissions to Petrinex. This screen can be launched from the menu or from the Explorer for Injection Facilities attached to a Control Group (available as of Release 25.1).

For Injection Facilities attached to a Control Group, the user must have access to the Control Group, along with a Control Group Role with Full Access to the InjectionBalanceEdit component. For those Injection Facilities not attached to a control group, the user must have a Corporate Role with Full Access to the InjectionBalanceEdit component.

When the Injection Facility is attached to a Control Group, the Injection Facility Balance screen will reset the Step status when any changes are made. In addition, if the control group is locked/closed (for at least STEP01 - Allocations), then no changes will be allowed (all fields and action buttons will be disabled).

Injection Balance Summary

This summary section appears at the top of the screen and is visible regardless of which tab is currently active. Metering Difference is a calculated volume based on all other data entry.

Note: The Project Injection column will only be visible as of Release 24.1. Project Injection is only available, and can therefore only be non-zero, for Injection Facilities in Saskatchewan and Manitoba (for dates after Manitoba implemented Petrinex).

When the Injection Facility is attached to a Control Group, the control group will appear as part of the header. If the Control Group is locked/closed (for at least STEP01 - Allocations) then no changes will be allowed on any of the tabs and a message will be displayed.

image-20241112-182655.png

 

Balance

This tab is used to enter Opening and Closing Inventory for the various products.

The Recalculate button on this tab will recalculate the summary information for the entire Injection Facility. This button will only be used rarely by clients, as the summary information is typically kept up to date as any changes are made to any of the volumes associated with the Injection Facility. This button was added as of Release 24.1 to deal with the change from summarizing various Gas By-products to the SOLVENT product to summarizing those products individually, so each Gas By-product would appear in the Summary and would be allowed to enter their own Opening/Closing Inventory.

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Product

This is a required field. 

Note: It will default to the first option in the drop-down.

Opening Inventory

Must be greater than or equal to 0.

Closing Inventory

Must be greater than or equal to 0.

 

Consumptions

This tab is used to enter consumption volumes used at the Injection Facility. The Consumptions tab will also display any entered receipt volumes that had the purpose of Lease Fuel, but that data is display-only on this tab and must be modified or deleted on the Receipts tab.

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Product

This is a required field. 

Note: It will default to the first option in the drop-down.

Usage ID

ID provided by the user to identify the consumption usage. Maximum size of 16 characters.

This is a required field.

Usage Type

Options include Flared, Lease Fuel, Vent, and Other.

Petrinex Activity

Options include FLARE, FUEL, VENT, PLTUSE, UTIL, and EMIS.

  • If left blank it will be automatically set based on Usage Type (Flared - FLARE, Lease Fuel - FUEL, Vent - VENT).

  • Must be FLARE when Usage Type is Flared.

  • Must be FUEL when Usage Type is Lease Fuel.

  • Must be VENT when Usage Type is Vent.

  • When a  Usage Type of Other is selected, the user must enter a Petrinex Activity code of PLTUSE, UTIL or EMIS

Volume

Must be greater than or equal to 0.

 

Production

This tab is used to enter any production that is to be reported at the Injection Facility.

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Well

Use typeahead.

Unique Well Identifier

This field is display-only.

Water Type

This field is display-only.

Producing Hours

Must be greater than or equal to 0 and cannot exceed the total possible hours in the production month.

Water Volume

Must be greater than or equal to 0.

Gas Volume

Must be greater than or equal to 0.

 

Receipts

This tab is used to enter receipts to the Injection Facility. This tab will also display receipts that were auto-generated based on dispositions from other Qbyte Metrix facilities. These auto-generated receipts cannot be modified or deleted.

The Load Facility Receipts button is used to ensure that dispositions into the Injection Facility from Batteries, Gathering Systems or Plants are in sync with receipts. This means that System Generated receipts may be added, deleted, or modified to ensure that they reflect the disposition data. This is only enabled if the Injection Facility has Automatically Generate Receipts set to No.

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Product

This is a required field. 

Note: It will default to the first option in the drop-down.

Receipt Type

This field is optional.

  • When the product is Gas, options include Lease Fuel from other source and blank.

  • When the product is H2O, FSHWTR, or BRKWTR, options include Water from well source, Water from unknown source and blank.

Transfer Entity Type

This field is optional. Options include Unit, BatteryDelivery SystemGGSInjection or Plant.

Transfer Entity ID

This field is optional. Use typeahead.

Seq. #

This field is display-only.

Note: Receipts auto-generated from dispositions at other Qbyte Metrix facilities may have a non-zero Sequence number, but receipts created on the Injection Facility Balance will only ever have a Sequence number of zero.

Volume

Must be greater than or equal to 0.

Gas Equivalent Factor

This field is optional.

Gas Equivalent Volume

This field is display-only. The value is calculated from the Volume and Gas Equivalent Factor.

Gigajoules

This field is optional. Must be greater than or equal to 0.

  • Only editable when the Product is GAS.

Report As Condensate

This field defaults to Spec and cannot be modified unless the product is Condensate, C3, C4, or C5. For these products, the options include Spec and Mix.

Purchased

This field can be Yes or No. It will default to No but can be modified on Gas or Raw Gas receipts.

Purpose Type

This field is optional.  It is used to indicate if the receipt was brought in to be used as Lease Fuel.

Note: If the product selected is also a valid product for consumption, then Purpose Type can be set to Lease Fuel. When set to Lease Fuel, the volume will also be displayed on the Consumptions tab and the volume will be included in the Summary section in both the Consumption and Receipts columns.

System Generated

This field is display-only.

 

Deliveries

This tab is used to enter deliveries from the Injection Facility. If the delivery is to an Injection Facility, where Automatically Generate Receipts is Yes, and it is attached to a Control Group that is locked/closed (for at least STEP01 - Allocations), then the delivery row will be protected from changes and/or deletions. In addition, no new deliveries to that Injection Facility can be created.

image-20241112-182058.png
image-20241112-182135.png
Destination Injection Facility is attached to a locked/closed Control Group

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Product

This is a required field. 

Note: It will default to the first option in the drop-down.

Delivery Type

This field is optional.

  • When the product is Water, options include Water to unknown destination and blank.

  • When the product is Skim Oil, options include Fire, Theft and blank.

  • For all other products, options include Fire and blank.

Transfer Entity Type

This field is optional. Options include BatteryDelivery SystemGGSInjection, Plant, or Unit .

Transfer Entity ID

This field is optional. Use typeahead.

Purchased

This field defaults to No.

Note: Only Gas deliveries can have purchased set to Yes.

Volume

Must be greater than or equal to 0.

Gigajoules

This field is optional. Must be greater than or equal to 0.

  • Only editable when the Product is GAS.

 

Injection

This tab is used to enter standard Injection and/or Disposal activities. For Petrinex reporting this corresponds to the INJ activity.

 

The Duplicate button can be used to quickly add new records. Select the row(s) you want to duplicate and then click the Duplicate button. The selected rows will be duplicated and added to the bottom of the grid. The newly added rows will remain editable so you can make the changes you need to make them unique.

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Well

Use typeahead.

Unique Well Identifier

This field is display-only.

CCI Code

This field is optional. Injection records that share a CCI code are grouped together on Save.

When more than one product is injected into a well, the CCI code is used to indicate whether the products were injected concurrently (at the same time) or consecutively (one after another).

  • The CCI code will only be required if an injection well is reporting injection for more than one product during the production month. The CCI code must be a number from 1 – 9.

  • When a well injects more than one product concurrently, a single CCI code and hours will be entered for that well. All the products and volumes injected concurrently will be entered for the well under the single CCI code and hours.

  • For consecutive injection activities, the well should be entered multiple times in the Injection grid. Each row for the well represents an injection activity, with a unique CCI number, product, volume, and the hours for that product.

  • The total injection hours for the well cannot exceed the maximum allowed for the production month.

Injected Hours

Must be greater than or equal to 0 and cannot exceed the total possible hours in the production month.

Pressure

This field is optional. Can only be entered if Injection Hours are non-zero.

  • The maximum size is 999999 and can be negative.

Note: For BC properties, the pressure must be between -5001 and 99999.

Temperature

This field is optional.

  • Can only be entered if Injection Hours are non-zero.

Note: For BC Injection Facilities and Production Dates greater than or equal to the BC Petrinex Implementation date, the Temperature must be between -20 and 99.9.

Product

This is a required field. 

Note: It will default to the first option in the drop-down.

Volume

Must be greater than or equal to 0.

  • Can only be entered if Injection Hours are non-zero.

Gigajoules

This field is optional. Must be greater than or equal to 0.

  • Only editable when the Product is GAS.

 

Project Injection (as of Release 24.1)

This tab is used to enter project-based injection (injection that must be reported using special *INJ Petrinex activities, like STINJ). This type of injection is only available for Saskatchewan and Manitoba (for dates that Manitoba has implemented Petrinex), so all fields and buttons will be disabled for any other province/date combination. 

For an Injection Facility in Saskatchewan or Manitoba, the tab would look like the following.

The Duplicate button can be used to quickly add new records. Select the row(s) you want to duplicate and then click the Duplicate button. The selected rows will be duplicated and added to the bottom of the grid. The newly added rows will remain editable so you can make the changes you need to make them unique.

FIELD

DESCRIPTION

FIELD

DESCRIPTION

Well

Use typeahead.

Unique Well Identifier

This field is display-only.

Injection Type

This is a required field.

  • Options include Enhanced Oil Recovery Project and Thermal NCG Project.

Product

This is a required field.

Note: It will default to the first option in the drop-down.

Volume

Must be greater than or equal to 0.

 


Copyright© 2024 IFS AB. Copying prohibited. All rights reserved.