Spreadsheet Import

Spreadsheet Import

Search the Qbyte Metrix Wiki
 

Back to Import or Export     Back to Well Maintenance    Back to Royalty Obligations     Back to How To Integrate Royalties    Back to How to Integrate Global Factors      Back to How To: Spreadsheet Import Partner Operated Sales     Back to Consumption Allocation Back to How To: Spreadsheet Import Default Price and Transportation Rates      Back to Qbyte Metrix Home


Introduction

Qbyte Metrix can import some master data from spreadsheets to make mass changes easier.

For example, imports can be used for:

  • Mass changes to well master data for multiple months – You no longer must open for amendment at Step 1 to perform a master change.

  • Oil/water gas ratios – Input oil/water gas ratios for many wells in a spreadsheet import to update all the wells at once.

  • Spring/fall fuel rates – Create two spreadsheet imports, one for spring and one for fall fuel rates. Import the appropriate spreadsheet as required.

  • Create complete or partial royalty obligations for multiple wells/tracts at once.

Templates

  • Four templates are available to import or modify well master data.

  • Seven templates have been provided to import or modify well factors and well consumption factors.

  • One template is available to delete well consumption factors.

  • One template is available to import or modify royalty global factors.

  • Two templates are available to import or modify royalty obligation factors.

  • Two templates are available to import royalty obligations.

  • One template is available to delete royalty obligations.

  • One template is available to create/update facility consumption usages.

  • One template is available to create entity linkages on facility consumption usages.

  • One template is available to delete entity linkages on facility consumption usages.

  • One template is available to update facility default price, deduction rates and transportation rates.

  • Four templates are available to import facility purchaser contract pricing information.

  • Four templates are available to import facility purchaser contract user input and/or override energy.

  • One template is available to update facility production overrides.

  • One template is available to update facility inventory overrides.

  • One template is available to update facility charge monthly input factors.

  • One template is available to update oil valuation transportation rates.

  • One template is available to update IOGC Gas Cost Allowance (GCA).

  • One template is available to update Partner Operated Sales Transactions.

  • One template is available to update Partner Operated Battery Prices.

  • One template is available to create entity-level Division of Interests.

  • Three templates are available to create/update owner master data.

  • Two templates are available to create entity-level DOI Exceptions.

Template ID

Template Description

Template Type ID

Usage

Template ID

Template Description

Template Type ID

Usage

DOIFACILITYCHARGEEXCPTN

Create Facility Charge DOI Exceptions

DOIEXCEPTIONS

  • Create Facility Charge DOI Exceptions for valid entities (Battery, Gathering System, Plant, Tract, Unit, Well).

  • User control group security access to DOIEdit will apply.

  • There will be no checks for locked/closed on impacted entities, and they will not be reset.

  • Available as of Release 23.4.

DOIMASTER

Create Entity Division of Interests

DOIMASTER

  • Create Division of Interests for valid entities (Battery, Gathering System, Injection Facility, Plant, Tract, Unit, Well).

  • User corporate security access to DOIImportByTemplate will apply.

  • There will be no checks for locked/closed on impacted entities, and they will not be reset.

  • Available as of Release 23.3.

DOIOWNEXCPTN

Create Ownership DOI Exceptions

DOIEXCEPTIONS

  • Create Ownership Charge DOI Exceptions for valid entities (Tract, Unit, Well).

  • User control group security access to DOIEdit will apply.

  • There will be no checks for locked/closed on impacted entities, and they will not be reset.

  • Available as of Release 23.4.

FACILITYCHARGEMONTHLYFACTORVALUE

Update Facility Charge Global Factor Value

FACILITYCHARGEGLOBALFACTORVALUE

  • Update Facility Charge Monthly Factor Values

  • User control group security access to FCGlobalFactorEdit will apply.

  • Impacted control groups must not be locked/closed for Step 4.

FACILITYCONSUSAGEENTITY

Create Entity Linkage on Facility Consumption Usage IDs

 FACILITYCONSUSAGE

  • Create Entity Linkage on Facility Consumption Usage IDs. Input volumes for Entity Linkages cannot be imported.

  • User control group security access to BatteryBalanceEdit, GGSBalanceEdit or PlantBalanceEdit will apply, depending upon the Facility Type being imported. 

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

FACILITYCONSUSAGEENTITYDELETE

Delete Entity Linkage on Facility Consumption Usage IDs

 FACILITYCONSUSAGE

  • Delete Entity Linkage on Facility Consumption Usage IDs.

  • User control group security access to BatteryBalanceEdit, GGSBalanceEdit or PlantBalanceEdit will apply, depending upon the Facility Type being imported. 

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

 FACILITYCONSUSAGEGENERAL

Create/Update Facility Consumption Usage IDs - No Input Volumes 

 FACILITYCONSUSAGE

  • Create/Update Facility Consumption Usage IDs. Input volumes for Usage IDs cannot be imported. To load input volumes for Usage IDs, use Field Data Capture and the CONSUSG layout.

  • User control group security access to BatteryBalanceEdit, GGSBalanceEdit or PlantBalanceEdit will apply, depending upon the Facility Type being imported. 

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

FACILITYDEFAULTPRICE

Update Facility Default Prices and Transportation Rates

FACILITYDEFAULTPRICE

  • Update Facility Default Prices, Deduction Rates and Transportation Rates. 

  • User control group access to PricingEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

FACILITYOVERRIDEPRODN

Update Facility Production Overrides

FACILITYOVERRIDE

  • Update Facility Production Overrides.

  • User control group security access to OverrideProductionEdit will apply.

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

FACILITYOVERRIDEOPNINV

Update Facility Opening Inventory Overrides

FACILITYOVERRIDE

  • Update Facility Opening Inventory Overrides.

  • User control group security access to OverrideOpeningInventoryEdit will apply.

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

INDIANROYALTYGCA

Update IOGC GCA by Royalty Entity ID

INDIANROYALTYPRICEUPDATE

  • Update Gas Cost Allowance by Royalty Entity Type and ID.

  • User corporate access to PriceByRoyaltyIDEdit will apply.

MMCONTRACTENERGY

Update Override GJs

MMCONTRACT

  • Update Facility Purchaser Contract Override Energy.

  • Purchaser Contract must be for the product GAS or RAWGAS.

  • Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix.

  • User control group security access to MarketMasterEdit will apply.

  • Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes applied.

  • Available as of Release 23.2.

MMCONTRACTENERGYBYDESC

Update Override GJs by Contract Description

MMCONTRACT

  • Update Facility Purchaser Contract Override Energy using Contract Description to identify Purchaser Contracts.

  • Purchaser Contract must be for the product GAS or RAWGAS.

  • When using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. If that occurs an error will be generated, and that data will not be imported.

  • User control group security access to MarketMasterEdit will apply.

  • Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes applied.

  • Available as of Release 23.2.

MMCONTRACTPRICING

Update Facility Purchaser Contract Pricing

MMCONTRACT

  • Update Facility Purchaser Contract Pricing data, including Price Code, Price/Value, Transportation Type/Cost, and Pricing Deduction Type/Cost.

  • Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix.

  • User control group access to PricingEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

MMCONTRACTPRICINGBYDESC

Update Facility Purchaser Contract Pricing by Contract Description

MMCONTRACT

  • Update Facility Purchaser Contract Pricing data, including Price Code, Price/Value, Transportation Type/Cost, and Pricing Deduction Type/Cost using Contract Description to identify Purchaser Contracts.

  • When using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. If that occurs an error will be generated, and that data will not be imported.

  • User control group access to PricingEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

MMCONTRACTUNITPRICE

Update Facility Purchaser Contract Unit Price

MMCONTRACT

  • Update Facility Purchaser Contract Unit Prices.

  • Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix. Purchaser Contract must be set up to use Price Per Unit.

  • User control group access to PricingEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

MMCONTRACTUNITPRICEBYDESC

Update Facility Purchaser Contract Unit Price by Contract Description

MMCONTRACT

  • Update Facility Purchaser Contract Unit Prices using Contract Description to identify Purchaser Contracts.

  • When using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. All matching records will be updated, if applicable (use Price Per Unit, are not locked/closed for Step03, etc.).

  • User control group access to PricingEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

MMCONTRACTUSERINPUT

Update User Input Volume and Override GJs

MMCONTRACT

  • Update Facility Purchaser Contract User Input Volume and Override Energy.

  • Purchaser Contract must have Allocation Method set to User Input. Import of Override Energy is only valid when product is GAS or RAWGAS.

  • Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix.

  • User control group security access to MarketMasterEdit will apply.

  • Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes applied.

  • Available as of Release 23.2.

MMCONTRACTUSERINPUTBYDESC

Update User Input Volume and Override GJs by Contract Description

MMCONTRACT

  • Update Facility Purchaser Contract User Input Volume and Override Energy using Contract Description to identify Purchaser Contracts.

  • Purchaser Contract must have Allocation Method set to User Input. Import of Override Energy is only valid when product is GAS or RAWGAS.

  • When using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. If that occurs an error will be generated, and that data will not be imported.

  • User control group security access to MarketMasterEdit will apply.

  • Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes applied.

  • Available as of Release 23.2.

OBLIGATIONFACTORVALUE

Update Royalty Obligation Factor Values

OBLIGATIONFACTORVALUE

  • Update the factor values for Royalty Obligation Factors. 

  • User control group security access to RoyaltiesEdit will apply.

OILVALUATIONTRANS

Update Oil Valuation RTP Overrides

OILVALUATIONTRANS

  • Update Oil Valuation Overrides for Oil Valuation RTP submissions.

  • User corporate access to OilValuation will apply.

OWNERGOVTCODEUPD

Update Owner Government Codes

OWNERMASTER

  • Update government codes for Owners.

  • User corporate security access to OwnerEdit will apply.

  • Available as of Release 23.4.

OWNERMASTER

Create/Update Owners

OWNERMASTER

  • Create a new Owner or update an existing Owner.

  • User corporate security access to OwnerImportByTemplate will apply.

  • Available as of Release 23.4.

OWNERNAMEADDRESSUPD

Update Owner Name and Addresses

OWNERMASTER

  • Update name, address lines and/or postal code for Owners.

  • User corporate security access to OwnerEdit will apply.

  • Available as of Release 23.4.

PARTNEROPPRICING

Create/Update Partner Operated Pricing

PARTNEROPPRICING

  • Create or Update Partner Operated Battery Prices.

  • User control group security access to PartnerOpBatteryBalanceEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

PARTNEROPSALES

Update Partner Operated Sales Transactions

PARTNEROPTRANSACTIONUPD

  • Update Net/Gross Volume, Net/Gross Value, Net/Gross GJs, Net/Gross Transportation, Net/Gross Quality Adjustment, Net/Gross Tariff, Net/Gross Line Loss, Net/Gross Other#1, and Net/Gross Other#2 on Sales Transactions for Partner Operated Wells. 

  • User control group security access to PartnerOpBatteryBalanceEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

ROYALTYGLOBALFACTOR

Create/Update Royalty Global Factor

ROYALTYGLOBALFACTOR

  • Create/update Royalty Global Factor Masters and Values.

  • User corporate security access to RoyaltyUserDefinedFactorCreateDelete and/or RoyaltyUserDefinedFactorEdit will apply.

ROYALTYOBLIGATION

Create/Update Royalty Obligation Masters

ROYALTYOBLIGATION

  • Create/update Royalty Obligation Masters

  • User control group security access to RoyaltiesEdit will apply.

ROYALTYOBLIGATIONDELETE

Delete Royalty Obligation Masters

ROYALTYOBLIGATION

  • Delete Royalty Obligation Masters.

  • User control group security access to RoyaltiesEdit will apply.

ROYALTYOBLIGATIONFACTOR

Create/Update Royalty Obligation Factor Masters

ROYALTYOBLIGATIONFACTOR

  • Create/update Royalty Obligation Factor Masters (ID and Description).

  • User corporate security access to RoyaltyUserDefinedFactorCreateDelete and/or RoyaltyUserDefinedFactorEdit will apply.

ROYALTYOBLIGATIONHDR

Create Pending Royalty Obligation Masters

ROYALTYOBLIGATIONHDR

  • Create Royalty Obligation Masters with minimal data and set Active Status to Pending.

  • User corporate security access to RoyaltiesImportByTemplate will apply.

WELLABOILCROWN

Update Alberta Well Oil Crown Factors

WELLPRODFACTORUPD

  • Update Alberta Well Oil Crown Factors (Oil Density, Crown Calculation Type, Equivalent Use Sub Type).

  • User control group security access to WellFactorsEdit will apply.

  • Available as of Release 24.4.

WELLCONSBYLABEL

Update Well Consumption Rates by Label

WELLCONSUMPTIONFACTORUPD

  • Update Rate on Well Consumption Factors using Label to identify the factor. 

  • User control group security access to WellFactorsEdit will apply.

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLCONSDELETEBYLABEL

Delete Well Consumption Factors

WELLCONSUMPTIONFACTORUPD

  • Delete Well Consumption Factors using Label to identify the factor. 

  • User control group security access to WellFactorsEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after deletions are applied.

WELLCONSUMPTION

Create/Update Well Consumption Factors

WELLCONSUMPTIONFACTOR

  • Create/update Well Consumption Factors.

  • User control group security access to WellFactorsEdit will apply.

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLCONSUMPTIONUPD

Update Well Consumption Factors

WELLCONSUMPTIONFACTORUPD

  • Update Well Consumption Factors (all fields) using Label to identify the factor. 

  • User control group security access to WellFactorsEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLMASTERCREATION

Create Well Masters

WELLMASTERCREATE

  • Create Well Masters

  • User corporate access to WellMaintenanceEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLMASTERGENERALUPD

Update Well Master General Data (UWI, Name, User-Defined, Pool, etc.)

WELLMASTERUPD

  • Update general fields (UWI, Name, Field, Pool, Depth, Cost Centre, Partner Operated Petrinex Id, User-Defined1 and User-Defined2) on Well Master

  • User control group security access to WellMaintenanceEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLMASTERGENERALUPDNORESET

Update Well Master General Data - No Reset (UWI, Name, User-Defined, Pool, etc.)

WELLMASTERUPDNOCHECK

  • Update general fields (UWI, Name, Field, Pool, Depth, Cost Centre, Partner Operated Petrinex Id, User-Defined1 and User-Defined2) on Well Master.

  • User corporate security access to ImportByTemplateNoReset will apply.

  • There will be no checks for locked/closed on impacted facilities, and they will not be reset.

WELLMASTERUWIUPDNORESET

Update Well Master UWI Data - No Reset

WELLMASTERUPDNOCHECK

  • Update UWI on Well Master.

  • User corporate security access to ImportByTemplateNoReset will apply.

  • There will be no checks for locked/closed on impacted facilities, and they will not be reset.

WELLPRODUCTIONFACTOR

Update Well Production Factors

WELLPRODFACTORUPD

  • Update any/all Well Production Factors

  • User control group security access to WellFactorsEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLWGR

Update Well Water Gas Ratio Factor

WELLPRODFACTORUPD

  • Update Well WGR Factor and/or Test Date

  • User control group security access to WellFactorsEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

WELLWGROGR

Update Well Water and Oil Gas Ratio Factors

WELLPRODFACTORUPD

  • Update Well WGR Factor, WGR Code, WGR Test Date, OGR Code, OGR Factor and OGR Test Date

  • User control group security access to WellFactorsEdit will apply. 

  • Impacted facilities must not be locked/closed for Step 1 and may be reset, if applicable, after changes are applied.

The format of sample templates can be generated from Import/Export > Template Based > Import Data by selecting a template and then clicking the Generate Sample button.

The template has a header row and an explanation/validation row. The second row provides the information/validation rules for populating the template. Reminder: This second row must always be deleted before importing.

  • See the Appendix section for additional information regarding templates.

When a template is used to update existing data, the exclamation mark can be used in columns that do not need to be updated.

  • See the Appendix section for examples on how to use the exclamation mark. 

When new Qbyte Metrix IDs are being created through an import, they should not contain leading spaces, multiple consecutive spaces, or trailing spaces.

 

DOIFACILITYCHARGEEXCPTN - Create Facility Charge DOI Exceptions (as of Release 23.4)

This template can be used to create entity-level DOI Facility Charge Exceptions. Valid entities are Battery, Gathering System, Plant, Tract, Unit and Well. You must also have Full Access to the control group security component DOIEdit.

 

DOIMASTER - Create Entity Division of Interests (as of Release 23.3)

This template can be used to create entity-level Division of Interests. Valid entities are Battery, Gathering System, Injection Facility, Plant, Tract, Unit and Well. You must also have Full Access to the corporate security component DOIImportByTemplate.

 

DOIOWNEXCPTN - Create Ownership DOI Exceptions (as of Release 23.4)

This template can be used to create entity-level DOI Ownership Exceptions. Valid entities are Tract, Unit and Well. You must also have Full Access to the control group security component DOIEdit.

 

FACILITYCHARGEMONTHLYFACTORVALUE - Update Facility Charge Monthly Factor Values

This template can be used to update Facility Charge Monthly Factor Values. This template will not create Facility Charge Monthly Factors. You must also have Full Access to the corporate security component FCGlobalFactorEdit.

 

FACILITYCONSUSAGEENTITY - Create Entity Linkages on Facility Consumption Usage IDs - No Input Volumes

This template can be used to create Entity Linkages on Facility Consumption Usage IDs. Input Volumes for Entity Linkages cannot be imported. User control group security access to BatteryBalanceEdit, GGSBalanceEdit or PlantBalanceEdit will apply, depending upon the Facility Type being imported. Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

 

FACILITYCONSUSAGEENTITYDELETE - Delete Entity Linkages on Facility Consumption Usage IDs

This template can be used to delete Entity Linkages on Facility Consumption Usage IDs. User control group security access to BatteryBalanceEdit, GGSBalanceEdit or PlantBalanceEdit will apply, depending upon the Facility Type being imported. Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

 

FACILITYCONSUSAGEGENERAL - Create/Update Facility Consumption Usage IDs - No Input Volumes

This template can be used to update Facility Consumption Usage IDs. Input Volumes for Usage IDs cannot be imported. To load input volumes for Usage IDs, use Field Data Capture and the CONSUSG layout. User control group security access to BatteryBalanceEdit, GGSBalanceEdit or PlantBalanceEdit will apply, depending upon the Facility Type being imported. Impacted facilities must not be locked/closed for Step 1 and may be Reset, if applicable, after changes are applied.

 

FACILITYDEFAULTPRICE - Update Facility Default Prices and Transportation Rates

This template can be used to update Facility Default Prices, Deduction Rates and Transportation Rates. You must also have Full Access to the PricingEdit control group security component, as this component is used to determine if you can create or update prices for the Facility or Production Date(s). 

 

FACILITYOVERRIDEPRODN - Update Facility Production Overrides

This template can be used to update Facility Production Overrides. You must also have Full Access to the OverrideProductionEdit control group security component, as this component is used to determine if you can update production overrides for the Facility or Production Date(s).

 

FACILITYOVERRIDEOPNINV - Update Facility Opening Inventory Overrides

This template can be used to update Facility Inventory Overrides. To generate the data for the template, see How to: Spreadsheet Import Facility Override Inventory You must also have Full Access to the OverrideOpeningInventoryEdit control group security component, as this component is used to determine if you can update production overrides for the Facility or Production Date(s).

 

INDIANROYALTYGCA - Update IOGC GCA by Royalty Entity ID

This template can be used to update the Gas Cost Allowance by Royalty Entity Type and ID. This template will not create Royalty Entity IDs. You must also have Full Access to the corporate security component   PriceByRoyaltyIDEdit.

MMCONTRACTENERGY - Update Contract Override Energy (as of Release 23.2)

This template can be used to update Facility Purchaser Contract Override Energy data. Contracts must be for product GAS or RAWGAS. Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix. You must also have Full Access to MarketMasterEdit control group security component. Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes are applied.

  • See the Template for MMCONTRACTENERGY section for the import format and sample data. Note: This data can also be exported from Qbyte Optix using the Facility Data Extract and the Commonly Used Attributes option of Purchaser Contract Override Energy.

 

MMCONTRACTENERGYYDESC - Update Contract Override Energy by Contract Description (as of Release 23.2)

This template can be used to update Facility Purchaser Contract Override Energy data using Contract Description to identify contract being updated. Contracts must be for product GAS or RAWGAS. When you are using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. If this occurs an error will be generated, and the data will not be imported. You must also have Full Access to the MarketMasterEdit control group security component. Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes are applied.

MMCONTRACTPRICING - Update Contract Pricing

This template can be used to update Facility Purchaser Contract Pricing data. Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix. You must also have Full Access to PricingEdit control group security component. Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

 

MMCONTRACTPRICINGBYDESC - Update Contract Pricing by Contract Description

This template can be used to update Facility Purchaser Contract Pricing data using Contract Description to identify contract being updated. When you are using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. If this occurs an error will be generated, and the data will not be imported. You must also have Full Access to the PricingEdit control group security component. Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

MMCONTRACTUNITPRICE - Update Contract Unit Prices

This template can be used to update Facility Purchaser Contract Unit Price. Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix. Purchaser Contract must be set up to use Price Per Unit. You must also have Full Access to PricingEdit control group security component. Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

 

MMCONTRACTUNITPRICEBYDESC - Update Contract Unit Prices by Contract Description

This template can be used to update Facility Purchaser Contract Unit Price using Contract Description to identify contract being updated. When you are using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. All matching records will be updated if applicable (use Price Per Unit, are not locked/closed for Step03, etc.). Only contracts set to use Price Per Unit will be updated. You must also have Full Access to PricingEdit control group security component. Impacted facilities must not be locked/closed for Step 3 and may be Reset, if applicable, after changes are applied.

MMCONTRACTUSERINPUT - Update Contract User Input and Override Energy (as of Release 23.2)

This template can be used to update Facility Purchaser Contract User Input Volume and Override Energy data. Contracts must have the Allocation Method set to User Input and the Override Energy will only be imported when the product is GAS or RAWGAS. Requires full key for identifying Facility Purchaser Contract. There must be an exact match to one and only one record within Qbyte Metrix. You must also have Full Access to MarketMasterEdit control group security component. Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes are applied.

  • See the Template for MMCONTRACTUSERINPUT section for the import format and sample data. Note: This data can also be exported from Qbyte Optix using the Facility Data Extract and the Commonly Used Attributes option of Purchaser Contract User Input.

 

MMCONTRACTUSERINPUTBYDESC - Update Contract User Input and Override Energy by Contract Description (as of Release 23.2)

This template can be used to update Facility Purchaser Contract User Input Volume and Override Energy data using Contract Description to identify contract being updated. Contracts must have the Allocation Method set to User Input and the Override Energy will only be imported when the product is GAS or RAWGAS. When you are using Contract Description there may be more than one matching Market Master Purchaser Contract record within Qbyte Metrix. If this occurs an error will be generated, and the data will not be imported. You must also have Full Access to the MarketMasterEdit control group security component. Impacted facilities must not be locked/closed for Step 2 and may be Reset, if applicable, after changes are applied.

 

OBLIGATIONFACTORVALUE - Update Royalty Obligation Factor Values

This template can be used to update Obligation Factor Values (Factor or Global Factor ID only). This template will not create any Obligation Factors. You must also have Full Access to the control group security component RoyaltiesEdit.

 

OILVALUATIONTRANS - Update Oil Valuation RTP Overrides

This template can be used to update Oil Valuation Overrides of Transportation and Quality Adjustment for RTP Submissions. This template will not create oil valuation override rows. You must also have Full Access to the corporate security component OilValuation.

OWNERGOVTCODEUPD - Update Owner Government Codes (as of Release 23.4)

This template can be used to update government codes for Owners. This template will not create Owner Masters, just update the government codes on existing Owners. You must have Full Access to the corporate security component OwnerEdit.

OWNERMASTER - Create/Update Owner Masters (as of Release 23.4)

This template can be used to create or update Owners. You must have Full Access to the corporate security component OwnerImportByTemplate.

 

OWNERNAMEADDRESSUPD - Update Owner Name and Addresses (as of Release 23.4)

This template can be used to update name, address lines, and postal code for Owners. This template will not create Owner Masters, just update the name, address lines and/or postal code on existing Owners. You must have Full Access to the corporate security component OwnerEdit.

PARTNEROPPRICING - Create/Update Partner Operated Pricing (as of Release 24.3)

This template can be used to create/update Partner Operated Pricing entries by Production Date, Battery, Transaction Type, Product, Plant, Purchaser/Royalty Owner ID, Purchaser Sequence, Destination Type, and Destination. You must also have Full Access to the Control Group security component PartnerOpBatteryBalanceEdit.

  • See the Template for PARTNEROPPRICING section for the import format and sample data. Note: This data can also be exported from Qbyte Optix using the Battery Data Extract and the Commonly Used Attributes option of Partner Operated Prices.

PARTNEROPSALES - Update Partner Operated Sales Transactions

This template can be used to update the Net/Gross Volume, Net/Gross Value, Net/Gross GJs, Net/Gross Transportation, Net/Gross Quality Adjustment, Net/Gross Tariff, Net/Gross Line Loss, Net/Gross Other#1, and Net/Gross Other#2 for Partner Operated Sales Transactions by Production Date, Battery, Well, Product, Purchaser ID, Purchaser Seq. #, Destination Type, and Destination ID. This template will not create Partner Operated Battery Sales transactions. To generate the data for the template, see How to: Import Partner Operated Sales Transactions. You must also have Full Access to the Control Group security component PartnerOpBatteryBalanceEdit.

ROYALTYGLOBALFACTOR - Create/Update Royalty Global Factor

This template can be used to create and/or update Royalty Global Factors. If the Royalty Global Factor from the Import file does not exist, the Royalty Global Factor will be created. If the Royalty Global Factor is found, all columns will be updated.

This template can be used when Royalty Global Factors need to be created for use within royalty formulas, or when the Royalty Global Factor value needs to be updated.

 

ROYALTYOBLIGATION - Create/Update Royalty Obligation Masters

This template can be used to create and/or update Royalty Obligation Masters. If the Royalty Obligation Master from the Import file does not exist, the Royalty Obligation Master will be created. If the Royalty Obligation Master is found, all columns will be updated.

You must have Full Access to the security component RoyaltiesEdit. After creating/updating royalty obligations, the facility/control group that the well/tract is attached to will not be reset.

If a Royalty Obligation is created/updated in a prior month, system-generated amendments will be created.

 

ROYALTYOBLIGATIONDELETE - Delete Royalty Obligation Masters

This template can be used to delete Royalty Obligation Masters. You must have Full Access to the security component RoyaltiesEdit. After deleting royalty obligations, the facility/control group that the well/tract is attached to will not be reset.

If a Royalty Obligation is deleted in a prior month, system-generated amendments will be created.

 

ROYALTYOBLIGATIONFACTOR - Create/Update Royalty Obligation Factors

This template can be used to create and/or update Royalty Obligation Factor Masters. If the Royalty Obligation Factor Master from the Import file does not exist, the Royalty Obligation Factor Master will be created. If the Royalty Obligation Factor Master is found, the description will be updated. You must also have Full Access to the corporate security component RoyaltyUserDefinedFactorCreateDelete and/or RoyaltyUserDefinedFactorEdit

 

ROYALTYOBLIGATIONHDR - Create Pending Royalty Obligation Masters

This template can be used to create Royalty Obligation Masters with only a subset of the fields required to create a Royalty Obligation. To update existing Royalty Obligations, the ROYALTYOBLIGATION template must be used. All Royalty Obligation Masters created using this template will be created with an Active status of Pending.

This is most useful when you do not have all the information (i.e., Formula) required to create the obligation. You must also have Full Access to the security component RoyaltiesImportByTemplate, as this component allows you to create royalty obligation headers. After creating new Royalty Obligations, the facility/control group that the well is attached to will not be reset.

 

WELLABOILCROWN - Update Alberta Well Oil Crown Factors (as of Release 24.4)

This template can be used to update various Oil crown fields (Oil Density, Crown Calculation Type, Equivalent Sub Use Type) for Alberta wells. You must have Full Access to the security component WellFactorsEdit, as this component allows you to update the Well Royalty Crown Factors for Alberta wells.

WELLCONSBYLABEL - Update Well Consumption Rates by Label

This template can be used to Import Consumption Factor Rates for existing Consumption Factors (monthly, if necessary). This template will not create Consumption Factors; it will only update existing Consumption Factors. You must also have Full Access to the security component WellFactorsEdit, as this component allows you to update the Well Consumption Factors. After updating the Well Consumption Factors, the facility/control group that the well is attached to will be reset.

 

WELLCONSDELETEBYLABEL - Delete Well Consumption Factors by Label

This template can be used to delete Well Consumption Factors. You must have Full Access to the security component WellFactorsEdit. After deleting the Well Consumption Factors, the facility/control group that the well is attached to will be reset.

 

WELLCONSUMPTION - Create/Update Well Consumption Factor

This template can be used to create and/or update Well Consumption Factors. If the Well Consumption Factor from the Import file does not exist, the Consumption Factor will be created. If the Well Consumption Factor is found, all columns will be updated.

This template can be used when Well Consumption Factors need to be added to wells, or when existing Well Consumption Factors need to be changed. You must also have Full Access to the security component WellFactorsEdit, as this component allows you to update the Well Consumption Factors. After updating the well, the facility/control group that the well is attached to will be reset.

 

WELLCONSUMPTIONUPD - Update Well Consumption Factors

This template can be used to update existing Well Consumption Factors. This template is like WELLCONSUMPTION; the difference is that this template cannot be used to add Well Consumption Factors. You must also have Full Access to the security component WellFactorsEdit, as this component allows you to update the Well Consumption Factors. After updating the well, the facility/control group that the well is attached to will be reset. 

 

WELLMASTERCREATION - Create Well Masters

This template can be used to create Well Masters. This template is most useful when you need to create many wells. You must also have Full Access to the security component WellMaintenanceEdit, as this component allows you to create new wells. 

 

WELLMASTERGENERALUPD - Update Well Master General Data

This template can only be used to update Well Master Data. You must also have Full Access to the security component WellMaintenanceEdit, as this component allows you to update the well. After updating the well, the facility/control group that the well is attached to will be reset. 

 

WELLMASTERGENERALUPDNORESET - Update Well Master General Data - No Reset

This template is like WELLMASTERGENERALUPD in the way of the columns available for update. However, this template will not check for Locked/Closed status, nor will it reset the facility/control group the well is attached to after the import. Instead of using the standard WellMaintenanceEdit security component, to use this template you must have Full Access to the security component ImportByTemplateNoReset.

 

WELLMASTERUWIUPDNORESET - Update Well Master UWI Data - No Reset

This template is like WELLMASTERGENERALUPDNORESET in the way that this template will not check for Locked/Closed status, nor will it reset the facility/control group the well is attached to after the import. Instead of using the standard WellMaintenanceEdit security component, to use this template you must have Full Access to the security component ImportByTemplateNoReset. This template can only be used to update the Location of the well.

 

WELLPRODUCTIONFACTOR - Update Well Production Factors

This template can be used to update all the Well Production Factors such as Water Gas Ratio Factor, Water Gas Ratio Test Date, Oil Meter Factor, etc. If it is a Saskatchewan well, the HOR/EOR Rate can be updated as well. Note: This data can also be exported from Qbyte Optix using the Well Data Extract and the Commonly Used Attributes option of Production Factors.

 

WELLWGR - Update Well Water Gas Ratio Factor

This template can be used to update only the water gas ratio and the water gas ratio test date. No other data elements are updated.

 

WELLWGROGR - Update Well Water and Oil Gas Ratio Factors

This template can be used to update the Water and Oil Gas Ratio Factors, Codes and Test Dates. No other data elements are updated.

Import by Template

Menu Option

The menu option to import can be found within Import / Export > Template Based > Import Data By Template.

Note: This menu will not be displayed unless you have Full Access to the ImportByTemplate security component.

Import Screen

Field

Description

Field

Description

Name

Can be left blank, or any name can be entered. If left blank, the name will default to Filename with Current Production Month (e.g., WELLCONDBYLABEL_AKEIMPW01W01_200804.CSV).

Template ID*

Can be either entered or selected using the Advanced Search > Search.

Comment

This is not mandatory and can be left blank. This comment can be used to describe the import.

Filename*

Click the Add button to find and add the file to import.

File Includes Header

Indicates if the .CSV being used to import includes a header row or not.

Entity Key Mapping

The selected Mapped by Entity will be used to find matching records in the second column of the .CSV file.

Valid Mapped By entities include:

  • ID – Qbyte Metrix ID

  • GOVT – Government Code

  • UWI – For Wells, this is the location (formatted location without survey system). For Tracts, this is the Legal Presentation.

  • UDF1 – User-defined 1

  • UDF2 – User-defined 2

  • REGTRY – Petrinex ID (i.e., AB BT 0000045) 
    For example: If the spreadsheet uses UWIs as the Well IDs then the Mapped By should be UWI. The default is Well ID.

Note: Not all templates will require fields with Key Mapping, and some may have multiple fields that can be mapped, each with their own Key Mapping values.

Generate Sample: Templates can be generated by clicking the Generate Sample button. When this button is clicked, the selected Template will open in .CSV format.

Submit: This button will submit the Import. If an Import by the same name has been previously submitted, a message will display asking if the previous results can be overwritten.

How to Import

You must first decide which template to use. (See the  Spreadsheet Import Templates  section.) Once that is decided, a sample file with the correct template format can be generated by following the steps below:

1. Navigate to the Import Data by Template screen and enter the Template ID.

2. Click the Generate Sample button.

Note: This step is not required with each import because once you have a sample you can continue to use it. However, the templates may change over time, so you may need to update your sample files from time to time.

The Generate Sample button opens an Excel screen with the template information. All templates will have two rows populated. The first row is a header row with column headings, and the second row provides details indicating how to populate the column. Both rows can be deleted once the actual data is entered, as you can import a file with or without column headings.

However, if you are importing a file with headings, we are assuming only one row of headings, so the row containing details about each column should be deleted. Data can be created/updated in the following ways:

  • Using the rules and information on the second row, you can manually enter the data that needs to be uploaded.

  • Use an external system (i.e., FDC System) to generate the template using the rules provided by P2.

Note: When importing a file to update existing Qbyte Metrix data, you cannot leave columns blank that you do not want to change, as blank may be a valid option for a lot of Qbyte Metrix data columns. Instead, for columns that are required in the Import file, but that you do not want to be modified, you should enter an exclamation mark (!). This tells the import to leave the data in that column as it was. When you are creating new data within an import, the exclamation mark (!) is not valid as there is no pre-existing data to leave as is.

Once the data is entered, the .CSV file should be saved (i.e., MyImport.CSV).

  • See the Appendix section for examples of templates with sample data.

Now that your data is ready:

3. Navigate back into the Import by Template screen. A Name is optional.

Note: If the name is not provided, the process will create a name for you. If left blank, the name will default to Filename with Current Production Month (e.g., WELLCONDBYLABEL_AKEIMPW01W01_200804.CSV).

4. Select your Template ID and then select the Add button to select the file. 

  • If the file you are importing contains a row for the column headers, leave the File Includes Header as Yes (default value).

  • If you removed all headers change this to No. If the Template ID you selected has fields that represent Qbyte Metrix entities, you may see rows in the Entity Key Mapping grid. 

  • You can choose the Mapping option you used when you entered the data into the file to be imported. 

Note: You must ensure that the method you used in the file is a valid option for the Template ID you selected.

5. Click the Submit button.

The Submit button will submit a job to import the data.

  • As shown below, the Process Monitor will provide the status of the job and all messages related to the Import process.

  • If there are errors, the Message Centre will display a message requesting you to look at the Import Process Status report within Qbyte Metrix Reporting. (See the Import Status report, Production > Interoperability > Metrix Imports, section below.) This report can also be accessed from within the Process Monitor for the Import by Template Process. Simply click the paper icon, and it will launch the corresponding Qbyte Optix report. 

  • If no errors exist, the message will indicate that the job completed successfully.

 

Import Status Report

The Import Status report (Production > Interoperability > Qbyte Metrix Imports) displays the imported data elements and all errors and warnings that occurred during the Import.

Appendix

DOIFACILITYCHARGEEXCEPTION (as of Release 23.4)

Template for DOIFACILITYCHARGEEXCEPTION

Template ID

Column Header

Description

Template ID

Column Header

Description

DOIFACILITYCHARGEEXCPTN

Effective Date

Effective Date of DOI Facility Charge Exception.

Format YYYYMM.

DOIFACILITYCHARGEEXCPTN

Entity Type

Entity type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

  • T (Tract)

  • U (Unit)

  • (Well)

DOIFACILITYCHARGEEXCPTN

Entity

Unique identifier for the Entity.

  • Must exist in Effective Date

DOIFACILITYCHARGEEXCPTN

DOI Sub ID

Unique ID for the Sub within the Entity.

  • Maximum size of 16 characters but it is recommended that you use 4 digits 0 filled (0001)

DOIFACILITYCHARGEEXCPTN

Product

Optional.

  • Must be a valid Facility Charge Product or blank (N/A - Not Applicable)

DOIFACILITYCHARGEEXCPTN

DOI Extension Number

Extension ID.

  • Maximum of 2 digits.

  • Must be between 0 and 99.

DOIFACILITYCHARGEEXCPTN

Charge Entity Type

Charge Entity type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

  • U (Unit)

DOIFACILITYCHARGEEXCPTN

Charge Entity

Unique Identifier for the Charge Entity.

  • Must exist in Effective Date

DOIFACILITYCHARGEEXCPTN

Charge Type

Charge Type.

  • Must be a valid Charge Type.

DOIFACILITYCHARGEEXCPTN

Revenue or Expense

Options are:

  • R (Revenue)  

  • E (Expense)

 

Sample Data for DOIFACILITYCHARGEEXCPTN Template

Effective Date

Entity Type

Entity

DOI Sub ID

Product

DOI Extension Number

Charge Entity Type

Charge Entity

Charge Type

Revenue or Expense

Effective Date

Entity Type

Entity

DOI Sub ID

Product

DOI Extension Number

Charge Entity Type

Charge Entity

Charge Type

Revenue or Expense

200804

B

RLT10

0006



5

B

RLT10

06

R

200804 

RLT28 

0010 

GAS

P

RLTP1

11

R

 

DOIMASTER (as of Release 23.3)

Template for DOIMASTER

Template ID

Column Header

Description

Template ID

Column Header

Description

DOIMASTER

Effective Date

Effective Date of Division of Interest.

Format YYYYMM.

DOIMASTER

Entity Type

Entity type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • I (Injection Facility)

  • P (Plant)

  • T (Tract)

  • U (Unit)

  • (Well)

DOIMASTER

Entity

Unique identifier for the Entity.

  • Must exist in Effective Date

DOIMASTER

DOI Sub ID

Unique ID for the Sub within the Entity.

  • Maximum size of 16 characters but it is recommended that you use 4 digits 0 filled (0001)

DOIMASTER

DOI User Defined#1

Optional:

  • Maximum size of 30 characters

Note: The value for this column will only be read from the first record for the Sub. Any values in this column on subsequent records for the Sub will be ignored.

DOIMASTER

Integration Default

Options are:

  • Y (Yes)  

  • N (No)

Note: The value for this column will only be read from the first record for the Sub. Any values in this column on subsequent records for the Sub will be ignored.

DOIMASTER

Owner ID

Unique Identifier for an Owner.

  • Must exist in Effective Date

DOIMASTER

Owner Interest Percent

Interest Percent

  • Maximum size of 999.99999999 (3v8).

  • Must be greater than or equal to 0 and less than or equal to 100

DOIMASTER

Silent Partner Parent ID

Unique Identifier for an Owner.

Optional.

  • Must exist in Effective Date

  • Must exist as an Owner in the DOI

  • Cannot be the same as the Owner ID

  • Silent Partner Parent ID cannot be an Owner that itself has a Silent Partner Parent

DOIMASTER

Exclude Owner

Options are:

  • Y (Yes)  

  • N (No)

DOIMASTER

DOI Sub Note

Optional:

  • Maximum 4000 characters

Note: The value for this column will only be read from the first record for the Sub. Any values in this column on subsequent records for the Sub will be ignored.

 

Sample Data for DOIMASTER Template

Effective Date

Entity Type

Entity

DOI Sub ID

DOI User Defined#1

Integration Default

Owner ID

Owner Interest Percent

Silent Partner Parent ID

Exclude Owner

DOI Sub Note

Effective Date

Entity Type

Entity

DOI Sub ID

DOI User Defined#1

Integration Default

Owner ID

Owner Interest Percent

Silent Partner Parent ID

Exclude Owner

DOI Sub Note

200804

B

RLT10

0006



N

999

100.00000000



N

Sub 0006 to be used for royalty obligations

200804 

RLT28 

0010 

UDF1

999

50.00000000



N



200804 

RLT28 

0010





VEN700

25.00000000



N



200804

RLT28

0010





VEN7000

25.00000000

VEN700

N



 

DOIOWNEXCEPTION (as of Release 23.4)

Template for DOIOWNEXCEPTION

Template ID

Column Header

Description

Template ID

Column Header

Description

DOIOWNEXCPTN

Effective Date

Effective Date of DOI Facility Charge Exception.

Format YYYYMM.

DOIOWNEXCPTN

Entity Type

Entity type.

Options include:

  • T (Tract)

  • U (Unit)

  • (Well)

DOIOWNEXCPTN

Entity

Unique identifier for the Entity.

  • Must exist in Effective Date

DOIOWNEXCPTN

DOI Sub ID

Unique ID for the Sub within the Entity.

  • Maximum size of 16 characters but it is recommended that you use 4 digits 0 filled (0001)

DOIOWNEXCPTN

Exception Type

Exception Type.

  • OWN - Ownership

  • CRWN - Crown

  • FRHD - Freehold

  • ORR - Override

  • FCLS - F-Class

  • INDIAN - IOGC

  • OTHER - Other

  • CRAQ - Crown Acquired

  • FHTX - Freehold Tax

  • XMPT - Exempt Federal

Units can only use CRWN, CRAQ, FHTX, XMPT exception types.

DOIOWNEXCPTN

Product

  • Must be a valid product.

When Exception Type is CRAQ, product must be OIL or GAS.

When the entity is a Saskatchewan Unit, product must be OIL or GAS.

As of Release 24.4, the product BYP can be used when the Exception Type is CRWN, FRHD, ORR, FCLS, or OTHER.

DOIOWNEXCPTN

DOI Extension Number

Extension ID.

  • Maximum of 2 digits.

  • Must be between 0 and 99.

When Exception Type is OWN, CRAQ, FHTX or XMPT, the Extension ID must be 1.

When entity is a Saskatchewan Well or Tract and the Exception Type is CRWN, the Extension ID must be 1.

When entity is a Unit not in Saskatchewan and the Exception Type is CRWN, the Extension ID must be 1.

 

Sample Data for DOIOWNEXCPTN Template

Effective Date

Entity Type

Entity

DOI Sub ID

Exception Type

Product

DOI Extension Number

Effective Date

Entity Type

Entity

DOI Sub ID

Exception Type

Product

DOI Extension Number

200804

W

RLT10W01

0006

OWN

OIL

1

200804 

SKUN1T1 

0005 

ORR

GAS

FACILITYCHARGEMONTHLYFACTORVALUE

Template for FACILITYCHARGEMONTHLYFACTORVALUE

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYCHARGEMONTHLYFACTORVALUE

Production Date

Format YYYYMM.

FACILITYCHARGEMONTHLYFACTORVALUE

Control Group

Control Group ID

  • Maximum 16 characters.

FACILITYCHARGEMONTHLYFACTORVALUE

Factor Level

Factor Level

Options are:

  • CHRG (Facility Charge)

  • FACL (Facility)

  • WELL (Facility Charge plus Well)

FACILITYCHARGEMONTHLYFACTORVALUE

Factor ID

Factor ID

  • Maximum 16 characters.

FACILITYCHARGEMONTHLYFACTORVALUE

Charge Entity Type

Entity Type of Facility Charge.

Options are:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

  • U (Unit)

FACILITYCHARGEMONTHLYFACTORVALUE

Charge Entity ID

Unique Identifier for Facility Charge Entity.

FACILITYCHARGEMONTHLYFACTORVALUE

Product

  • Optional

  • Product of Facility Charge.

FACILITYCHARGEMONTHLYFACTORVALUE

Charge Type

Charge Type

  • Maximum 16 characters.

FACILITYCHARGEMONTHLYFACTORVALUE

Facility Charge Sequence 

Facility Charge Sequence

  • Maximum 4 digits.

FACILITYCHARGEMONTHLYFACTORVALUE

Well/Tract Type

Well/Tract Type. Can be left blank for Default Source Well.

Non-blank options:

  • W (Well)

  • T (Tract)

FACILITYCHARGEMONTHLYFACTORVALUE

Well/Tract

Unique Identifier for Well/Tract. Can be left blank.

FACILITYCHARGEMONTHLYFACTORVALUE

Factor Value

Maximum size of 9999999999.99999999 (10v8).

Sample Data for FACILITYCHARGEMONTHLYFACTORVALUE Template

Production Date

Control Group

Factor Level

Factor ID

Charge Entity Type

Charge Entity ID

Product

Charge Type

Facility Charge Sequence

Well/Tract Type

Well/Tract

Factor Value

Production Date

Control Group

Factor Level

Factor ID

Charge Entity Type

Charge Entity ID

Product

Charge Type

Facility Charge Sequence

Well/Tract Type

Well/Tract

Factor Value

201407

55501

FACL

BTYFAC

B

TGWBAT02





0





2.50

201407

AKEABFC

CHRG

82FACT

P

AKEABFCPL01

GAS

81

5





82.00

201407

AKEABFC2

WELL

GF-FCW

B

AKEABFCB04

OIL

97

5

W

AKEABFCB04W01

0.75

201407

AKEABFC2

WELL

GF-FCW

B

AKEABFCB04

OIL

97

5

W

AKEABFCB04W02

2.50

Facility Charge Monthly Factor Values After Importing - FACILITYCHARGEMONTHLYFACTORVALUE

 

FACILITYCONSUSAGEENTITY

Template for FACILITYCONSUSAGEENTITY

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYCONSUSAGEENTITY

Production Date

Format YYYYMM.

FACILITYCONSUSAGEENTITY

Facility Type

Facility type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

FACILITYCONSUSAGEENTITY

Facility

Unique identifier for the Facility.

FACILITYCONSUSAGEENTITY

Usage ID

Unique ID for the Usage within the Facility.

FACILITYCONSUSAGEENTITY

Well/Tract Type

Options are:

  • W (Well)

  • T (Tract)

FACILITYCONSUSAGEENTITY

Well/Tract ID

Unique identifier for the Well/Tract.

Note: This cannot be used to update the Input Volume for an Entity Linkage.

Sample Data for FACILITYCONSUSAGEENTITY Template

Production Date

Facility Type

Facility ID

Usage ID

Well/Tract Type

Well/Tract ID 

Production Date

Facility Type

Facility ID

Usage ID

Well/Tract Type

Well/Tract ID 

200804

P

RLT GFCPNP1

TREATA

 W

RLTGFCPNB1W01

200804 

RLT GFCPNP1 

TREATB 

 T

GFCPNUT1 

200804 

RLTGFCPNG1 

FUEL1

W

RLTGFCPNB2W01 

 

FACILITYCONSUSAGEENTITYDELETE

Template for FACILITYCONSUSAGEENTITYDELETE

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYCONSUSAGEENTITYDELETE

Production Date

Format YYYYMM.

FACILITYCONSUSAGEENTITYDELETE

Facility Type

Facility type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

FACILITYCONSUSAGEENTITYDELETE

Facility

Unique identifier for the Facility.

FACILITYCONSUSAGEENTITYDELETE

Usage ID

Unique ID for the Usage within the Facility.

FACILITYCONSUSAGEENTITYDELETE

Well/Tract Type

Options are:

  • W (Well)

  • T (Tract)

FACILITYCONSUSAGEENTITYDELETE

Well/Tract ID

Unique identifier for the Well/Tract.

 

Sample Data for FACILITYCONSUSAGEENTITYDELETE Template

Production Date

Facility Type

Facility ID

Usage ID

Well/Tract Type

Well/Tract ID 

Production Date

Facility Type

Facility ID

Usage ID

Well/Tract Type

Well/Tract ID 

200804

P

RLT GFCPNP1

TREATA

 W

RLTGFCPNB1W01

200804 

RLT GFCPNP1 

TREATB 

 T

GFCPNUT1 

200804 

RLTGFCPNG1 

FUEL1

W

RLTGFCPNB2W01 

 

FACILITYCONSUSAGEGENERAL

Template for FACILITYCONSUSAGEGENERAL

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYCONSUSAGEGENERAL

Production Date

Format YYYYMM.

FACILITYCONSUSAGEGENERAL

Facility Type

Facility type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

FACILITYCONSUSAGEGENERAL

Facility

Unique identifier for the Facility.

FACILITYCONSUSAGEGENERAL

Usage ID

Unique ID for the Usage within the Facility.

FACILITYCONSUSAGEGENERAL

Label

Unique Label for the Usage within the Facility.

FACILITYCONSUSAGEGENERAL

Usage Type

Options are:

  • ACID (Acid Gas)

  • FLAR (Flare)

  • FUEL (Lease Fuel)

  • VENT (Vent)

  • MD (Metering Difference) 

FACILITYCONSUSAGEGENERAL  

Proration Basis 

Can be left blank (Gathered Volume Only). 

Non-blank options are:

  • N2 (Nitrogen)

  • CO2 (Carbon Dioxide)

  • H2S (Hydrogen Sulphide)

  • C1 (Methane)

  • C2 (Ethane)

  • C3 (Propane)

  • IC4 or NC4 (Butane)

  • IC5 or NC5 (Pentane)

  • C6 (Hexane)

  • C7 (Heptane Plus)

FACILITYCONSUSAGEGENERAL  

Petrinex Province Code

Optional.

FACILITYCONSUSAGEGENERAL  

Petrinex Facility Type

Optional.

FACILITYCONSUSAGEGENERAL  

Petrinex Government Code

Optional.

FACILITYCONSUSAGEGENERAL  

Petrinex Activity Code

Optional. This is only valid for Plants and Usage Type = ACID and must be blank or FLARE.

FACILITYCONSUSAGEGENERAL  

Distribution Percent 

Maximum size of 999.99999999 (3v8). Must be greater than or equal to 0 and less than or equal to 100.

FACILITYCONSUSAGEGENERAL  

 Adjust Theoretical

Options are:

  • Y (Yes)  

  • N (No)

Note: This cannot be used to update the Input Volume for a Usage ID. To load input volumes for Usage IDs, use Field Data Capture and the CONSUSG layout.

Sample Data for FACILITYCONSUSAGEGENERAL Template

Production Date

Facility Type

Facility ID

Usage ID

Label 

Usage Type 

Proration Basis 

Petrinex Province 

Petrinex Type 

Petrinex Gov't Code 

Petrinex Activity 

Distribution Percent 

Adjust Theoretical 

Production Date

Facility Type

Facility ID

Usage ID

Label 

Usage Type 

Proration Basis 

Petrinex Province 

Petrinex Type 

Petrinex Gov't Code 

Petrinex Activity 

Distribution Percent 

Adjust Theoretical 

200804

P

RLT GFCPNP1

TREATA

 treater a

FUEL













Y

200804 

RLT GFCPNP1 

TREATB 

 treater b

FUEL 













Y

200804 

RLTGFCPNG1 

FUEL1

 compres1

FUEL 



AB 

CS 

0000034 





N

FACILITYDEFAULTPRICE

Template for FACILITYDEFAULTPRICE

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYDEFAULTPRICE

Production Date

Format YYYYMM.

FACILITYDEFAULTPRICE

Facility Type

Facility type.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

FACILITYDEFAULTPRICE

Facility

Unique identifier for the facility.

FACILITYDEFAULTPRICE

Product

Must be a valid producing product for the facility.

FACILITYDEFAULTPRICE

Price

Maximum size of 9999.99999999 (4v8).

FACILITYDEFAULTPRICE

Transportation Rate

Maximum size of 99999999.99999 (8v5).

FACILITYDEFAULTPRICE

Quality Adj. Rate

Maximum size of 99999999.99999 (8v5).

FACILITYDEFAULTPRICE

Tariff Rate

Maximum size of 99999999.99999 (8v5).

FACILITYDEFAULTPRICE

Line Loss Rate

Maximum size of 99999999.99999 (8v5).

FACILITYDEFAULTPRICE

Other#1 Rate

Maximum size of 99999999.99999 (8v5).

FACILITYDEFAULTPRICE

Other#2 Rate

Maximum size of 99999999.99999 (8v5).

Note: This is an update only template; the Price, Transportation Rate, Quality Adj. Rate, Tariff Rate, Line Loss Rate, Other#1 Rate, and the Other#2 Rate are the only columns that can be updated.

Sample Data for FACILITYDEFAULTPRICE Template

Production Date

Facility Type

Facility

Product

Price

Transportation Rate

Production Date

Facility Type

Facility

Product

Price

Transportation Rate

201406

B

AKEUHOLB04

OIL

360.63

2.50

201406

B

AKEUHOLB03

OIL

355.9

2.50

201406

P

AKEUHOLP02

GAS

2.90123

0

201406

B

AKEABGFB04

RAWGAS

2

0

201406

B

AKEABGFB04

OIL

289.54

2.50

201406

G

AKEABGFGGS3

COND

349.12

1.85

201406

P

AKEABGFPLT1

GAS

2.12

0

201406

P

AKEABGFPLT1

C2

-10.706897

0

201406

P

AKEABGFPLT1

C4SP

401.85

.85

201406

P

AKEABGFPLT1

C4MX

445.35

.85

FACILITYOVERRIDEPRODN

Template for FACILITYOVERRIDEPRODN

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYOVERRIDEPRODN

Production Date

Format YYYYMM.

FACILITYOVERRIDEPRODN

Facility Type

  • Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

FACILITYOVERRIDEPRODN

Facility

  • Facility

    • Unique identifier for Facility.

FACILITYOVERRIDEPRODN

Product

  • Product

    • Must be a valid producing product for Facility.

FACILITYOVERRIDEPRODN

Well/Tract Type

  • Well/Tract Type

    • W (Well)

    • T (Tract)

    • Can be left blank for Default Source Well.

FACILITYOVERRIDEPRODN

Well/Tract

  • Well/Tract

    • Unique identifier for Well, Tract, or Default Source Well (Outside Receipt).

FACILITYOVERRIDEPRODN

Owner ID

  • Owner ID

    • Unique identifier for Owner.

FACILITYOVERRIDEPRODN

Producing Battery

  • Producing Battery

    • Unique identifier for Producing Battery.

FACILITYOVERRIDEPRODN

Sending Battery

  • Sending Battery

    • Unique identifier for Sending Battery.

FACILITYOVERRIDEPRODN

Flow Group ID

  • Flow Group ID

    • Optional. Only valid for Gas Flow facilities where the product is not a Balance Only product.

    • Unique Identifier for Flow Group

  • Available as of Release 24.4.

FACILITYOVERRIDEPRODN

Production Volume

  • Production Volume

    • Maximum size of 999999999.9 (9v1).

    • Must be greater than or equal to 0.

Note: This is an update only template. The facility production overrides must have already been created in Qbyte Metrix prior to importing any updates.

Sample Data for FACILITYOVERRIDEPRODN Template

Production Date

Facility Type

Facility

Product

Well/Tract Type

Well/Tract

Owner ID

Producing Battery

Sending Battery

Flow Group ID

Production Volume

Production Date

Facility Type

Facility

Product

Well/Tract Type

Well/Tract

Owner ID

Producing Battery

Sending Battery

Flow Group ID

Production Volume

200804

P

RLT GFCPNP1

C3

W

RLTGFCPNB1W01

1

RLTGFCPNB1

RLTGFCPNB1

RLTWHOLE

0.4

200804

P

RLT GFCPNP1

C3

W

RLTGFCPNB1W01

VEN67756

RLTGFCPNB1

RLTGFCPNB1

RLTWHOLE

10.6

200804

P

RLTCPNP1

C3

T

CPNUT2

VEN67756

 



 

65.4

200804

P

RLTCPNP1

C3

W

RLTCPNB1W01

999

RLTCPNB1

RLTCPNB1

 

2.0

FACILITYOVERRIDEOPNINV

Template for FACILITYOVERRIDEOPNINV

Template ID

Column Header

Description

Template ID

Column Header

Description

FACILITYOVERRIDEOPNINV

Production Date

Format YYYYMM.

FACILITYOVERRIDEOPNINV

Facility Type

  • Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

FACILITYOVERRIDEOPNINV

Facility

  • Facility

    • Unique identifier for Facility.

FACILITYOVERRIDEOPNINV

Product

  • Product

    • Must be a valid producing product for Facility.

FACILITYOVERRIDEOPNINV

Well/Tract Type

  • Well/Tract Type

    • W (Well)

    • T (Tract)

    • Can be left blank for Default Source Well.

FACILITYOVERRIDEOPNINV

Well/Tract

  • Well/Tract

    • Unique identifier for Well, Tract, or Default Source Well (Outside Receipt).

FACILITYOVERRIDEOPNINV

Owner ID

  • Owner ID

    • Unique identifier for Owner.

FACILITYOVERRIDEOPNINV

Participant Type

  • Participant Type

    • CRWN (Crown Royalty)

    • EXVA (Exchange Owner - Financial)

    • EXVO (Exchange Owner - Volumetric)

    • RLO (Recovered Injection)

    • ROY (Production Royalty)

    • WIO (Working Interest Owner)

    • XCRWN (Crown Royalty Transfer)

    • XRLO (Recovered Injection Transfer)

    • XROY (Production Royalty Transfer)

    • XWIO (Working Interest Transfer)

FACILITYOVERRIDEOPNINV

Producing Battery

  • Producing Battery

    • Unique identifier for Producing Battery.

FACILITYOVERRIDEOPNINV

Sending Battery

  • Sending Battery

    • Unique identifier for Sending Battery.

FACILITYOVERRIDEOPNINV

Flow Group ID

  • Flow Group ID

    • Optional. Only valid for Gas Flow facilities where the product is not a Balance Only product. Must be blank when the product is OIL, even for Gas Flow batteries.

    • Unique Identifier for Flow Group

  • Available as of Release 24.4.

FACILITYOVERRIDEOPNINV

Reference Owner

  • Reference Owner

    • Optional. Should be populated when Participant Type is CRWN, ROY, XCRWN or XROY.

    • Unique Identifier for Reference Owner.

FACILITYOVERRIDEOPNINV

Obligation Product

  • Obligation Product

    • Optional. Should be populated when Participant Type is ROY or XROY.

    • Must be a valid royalty obligation product, if populated.

FACILITYOVERRIDEOPNINV

Obligation Number

  • Obligation Number

    • Optional. Should be populated when Participant Type is ROY or XROY.

    • A four-character field that must contain only digits typically containing leading zeros (i.e., 0001).

FACILITYOVERRIDEOPNINV

Inventory Volume

  • Inventory Volume

    • Maximum size of 999999999.9 (9v1).

Note: This is an update only template. The facility opening inventory overrides must have already been created in Qbyte Metrix prior to importing any updates.

Sample Data for FACILITYOVERRIDEOPNINV Template

Production Date

Facility Type

Facility

Product

Well/Tract Type

Well/Tract

Owner ID

Participant Type

Producing Battery

Sending Battery

Flow Group ID

Reference Owner

Obligation Product

Obligation Number

Inventory Volume

Production Date

Facility Type

Facility

Product

Well/Tract Type

Well/Tract

Owner ID

Participant Type

Producing Battery

Sending Battery

Flow Group ID

Reference Owner

Obligation Product

Obligation Number

Inventory Volume

200804

B

RLTCPNB1

OIL

W

RLTCPNB1W01

10114

CRWN

RLTCPNB1

RLTCPNB1

 

VEN7000





0.4

200804

B

RLTCPNB1

OIL

W

RLTCPNB1W01

10114

CRWN

RLTCPNB1

RLTCPNB1

 

999





0.6

200804

B

RLTCPNB1

OIL

W

RLTCPNB1W01

VEN7000

WIO

RLTCPNB1

RLTCPNB1

 







20.5

200804

B

RLTCPNB1

OIL

W

RLTCPNB1W01

999

WIO

RLTCPNB1

RLTCPNB1

 







36.8

200804

B

RLTCPNB1

OIL

W

RLTCPNB1W01

11

ROY

RLTCPNB1

RLTCPNB1

 

VEN7000

OIL

0001

1.2

200804

B

RLTCPNB1

OIL

W

RLTCPNB1W01

11

ROY

RLTCPNB1

RLTCPNB1

 

999

OIL

0001

2.8

INDIANROYALTYGCA

Template for INDIANROYALTYGCA

Template ID

Column Header

Description

Template ID

Column Header

Description

INDIANROYALTYGCA

Production Date

Format YYYYMM.

INDIANROYALTYGCA

Royalty Entity Type

Royalty Entity Type

Options include:

  • R (Royalty Entity)

INDIANROYALTYGCA

Royalty Entity ID

Royalty Entity ID

  • Maximum 16 characters.

INDIANROYALTYGCA

Gas Cost Allowance

Gas Cost Allowance

  • This must be greater than or equal to 0 and a maximum size of 999.9999 (3v4).

Note: This is an update only template; the Gas Cost Allowance is the only column that can be updated.

Sample Data for INDIANROYALTYGCA Template

Production Date

Royalty Entity Type

Royalty Entity ID

Gas Cost Allowance

Production Date

Royalty Entity Type

Royalty Entity ID

Gas Cost Allowance

201407

R

ROY-ID-123

15.012

201407

R

ROY-ID-124

133.0

201407

R

ROY-ID-126

101.1234

201407

R

ROY-ID-129

10.5

MMCONTRACTENERGY (as of Release 23.2)

Template for MMCONTRACTENERGY

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTENERGY

Production Date

Production Date

  • Format YYYYMM.

MMCONTRACTENERGY

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTENERGY

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTENERGY

Product

Product

  • Must be GAS or RAWGAS.

  • Must be a valid producing product for Facility.

MMCONTRACTENERGY

Disposition Type

Disposition Type

Options include:

  • DELV (Delivery)

  • XFER (Transfer)

  • INJ (Injection)

  • XI (Inventory Transfer)

  • LF (Return Consumption)

  • LF99 (Purchased Consumption)

  • XFRM (Transfer for Market)

  • XCONS (Transfer for Consumption)

  • XFUEL (Transfer for Fuel)

  • FS (Fuel Sale)

  • XP (Plant to Plant)

  • EX1 (Owner to Owner Transfer)

  • EX2 (Owner to Owner Sale)

MMCONTRACTENERGY

Destination Type

Destination Type

  • Optional. Not all Disposition Types require a Destination (i.e., Fire, Theft).

Options include:

  • B (Battery)

  • D (Delivery System)

  • G (Gathering System)

  • I (Injection Facility)

  • P (Plant)

MMCONTRACTENERGY

Destination ID

Destination ID

  • Unique identifier for Destination Facility or Delivery System.

  • Optional. Must be populated when Destination Type is populated.

MMCONTRACTENERGY

Disposition Sequence

Disposition Sequence

  • Maximum size of 9999.

MMCONTRACTENERGY

Allocation Number

Allocation Number

  • Maximum size of 99.

MMCONTRACTENERGY

Purchaser Type

Purchaser Type

Options include:

  • PURCH (Purchaser)

  • XFER (Facility Transfer)

  • LOSS (Loss - Fire Theft Spill or Shrinkage)

  • DILGS (Dilution Gas)

  • RETFL (Netted Return Fuel)

MMCONTRACTENERGY

Purchaser ID

Purchaser ID

  • Unique Identifier for Purchaser.

  • Optional. Must be populated when Purchaser Type = PURCH.

MMCONTRACTENERGY

Purchaser Sequence

Purchaser Sequence

  • Maximum size of 99.

MMCONTRACTENERGY

Override Energy

Override Energy (GJs)

  • Maximum size of 999999999999 (12v0).

  • Cannot be negative.

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates.

Sample Data for MMCONTRACTENERGY Template

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

Override Energy (GJs)

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

Override Energy (GJs)

200804

P

RLTCPNP1

GAS

DELV

D

ALLIAD

0

2

PURCH

VEN1002

0

15245

MMCONTRACTENERGYBYDESC (as of Release 23.2)

Template for MMCONTRACTENERGYBYDESC

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTENERGYBYDESC

Production Date

Production Date

Format YYYYMM.

MMCONTRACTENERGYBYDESC

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTENERGYBYDESC

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTENERGYBYDESC

Product

Product

  • Must be GAS or RAWGAS.

  • Must be a valid producing product for Facility.

MMCONTRACTENERGYBYDESC

Contract Description

Contract Description

  • Maximum size of 60 characters.

MMCONTRACTENERGYBYDESC

Override Energy

Override Energy (GJs)

  • Maximum size of 999999999999 (12v0).

  • Cannot be negative.

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates. There may be more than one market master facility purchaser contract with the same Contract Description; an error will be generated when more than one valid matching contract found.

Sample Data for MMCONTRACTENERGYBYDESC Template

Production Date

Facility Type

Facility ID

Product

Contract Description

Override Energy (GJs)

Production Date

Facility Type

Facility ID

Product

Contract Description

Override Energy (GJs)

200804

P

RLTCPNP1

GAS

RLT23

16248

MMCONTRACTPRICING

Template for MMCONTRACTPRICING

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTPRICING

Production Date

Production Date

  • Format YYYYMM.

MMCONTRACTPRICING

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTPRICING

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTPRICING

Product

Product

  • Must be a valid producing product for Facility.

MMCONTRACTPRICING

Disposition Type

Disposition Type

Options include:

  • DELV (Delivery)

  • XFER (Transfer)

  • INJ (Injection)

  • XI (Inventory Transfer)

  • LF (Return Consumption)

  • LF99 (Purchased Consumption)

  • XFRM (Transfer for Market)

  • XCONS (Transfer for Consumption)

  • XFUEL (Transfer for Fuel)

  • FIRE (Fire)

  • SPILL (Spill)

  • THEFT (Theft)

  • BLEND (Blending Shrinkage)

  • FS (Fuel Sale)

  • XP (Plant to Plant)

  • EX1 (Owner to Owner Transfer)

  • EX2 (Owner to Owner Sale)

MMCONTRACTPRICING

Destination Type

Destination Type

  • Optional. Not all Disposition Types require a Destination (i.e., Fire, Theft).

Options include:

  • B (Battery)

  • D (Delivery System)

  • G (Gathering System)

  • I (Injection Facility)

  • P (Plant)

MMCONTRACTPRICING

Destination ID

Destination ID

  • Unique identifier for Destination Facility or Delivery System.

  • Optional. Must be populated when Destination Type is populated.

MMCONTRACTPRICING

Disposition Sequence

Disposition Sequence

  • Maximum size of 9999.

MMCONTRACTPRICING

Allocation Number

Allocation Number

  • Maximum size of 99.

MMCONTRACTPRICING

Purchaser Type

Purchaser Type

Options include:

  • PURCH (Purchaser)

  • XFER (Facility Transfer)

  • LOSS (Loss - Fire Theft Spill or Shrinkage)

  • DILGS (Dilution Gas)

  • RETFL (Netted Return Fuel)

MMCONTRACTPRICING

Purchaser ID

Purchaser ID

  • Unique Identifier for Purchaser.

  • Optional. Must be populated when Purchaser Type = PURCH.

MMCONTRACTPRICING

Purchaser Sequence

Purchaser Sequence

  • Maximum size of 99.

MMCONTRACTPRICING

Price Code

Price Code

Options include:

  • DFLT (Default Price)

  • UNIT (Price Per Unit)

  • CONTRT (Total Contract Value)

  • ZERO (Zero Price)

MMCONTRACTPRICING

Input Price

Input Price

  • Optional. Only applicable when Price Code = UNIT.

  • Maximum size of 9999.99999999 (4v8).

MMCONTRACTPRICING

Value

Contract Value

  • Optional. Only applicable when Price Code = CONTRT.

  • Maximum size of 999999999.99 (9v2)

MMCONTRACTPRICING

Transportation Type

Transportation Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICING

Transportation Rate/Value

Transportation Rate/Value

  • Optional. Only applicable when Transportation Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

MMCONTRACTPRICING

Quality Adj. Type

Quality Adjustment Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICING

Quality Adj. Cost

Quality Adjustment Rate/Value

  • Optional. Only applicable when Quality Adj. Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICING

Tariff Fee Type

Tariff Fee Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICING

Tariff Cost

Tariff Fee Rate/Value

  • Optional. Only applicable when Tariff Fee Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICING

Line Loss Type

Line Loss Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICING

Line Loss

Line Loss Rate/value

  • Optional. Only applicable when Line Loss Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICING

Other#1 Fee Type

Other#1 Fee Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICING

Other#1 Cost

Other#1 Fee Rate/Value

  • Optional. Only applicable when Other#1 Fee Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICING

Other#2 Fee Type

Other#2 Fee Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICING

Other#2 Cost

Other#2 Fee Rate/Value

  • Optional. Only applicable when Other#2 Fee Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates.

Sample Data for MMCONTRACTPRICING Template

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

Price Code

Input Price

Value

Transportation Type

Transportation Type/Value

Quality Adj. Type

Quality Adj. Cost

Tariff Fee Type

Tariff Cost

Line Loss Type

Line Loss

Other#1 Fee Type

Other#1 Cost

Other#2 Fee Type

Other#2 Cost

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

Price Code

Input Price

Value

Transportation Type

Transportation Type/Value

Quality Adj. Type

Quality Adj. Cost

Tariff Fee Type

Tariff Cost

Line Loss Type

Line Loss

Other#1 Fee Type

Other#1 Cost

Other#2 Fee Type

Other#2 Cost

200804

B

RLTT9

OIL

DELV

D

7341O

0

2

PURCH

VEN1002

0

UNIT

251.15



RATE

1.25

RATE

.45

NA

0

DFLT

0

NA

0

VALUE

12.45

200804

B

RLTT9

OIL

DELV

D

7341O

0

3

PURCH

115874

0

VALUE

0

15482.25

VALUE

852.25

RATE

.48

NA

0

RATE

.14

NA

0

NA

0

MMCONTRACTPRICINGBYDESC

Template for MMCONTRACTPRICINGBYDESC

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTPRICINGBYDESC

Production Date

Production Date

Format YYYYMM.

MMCONTRACTPRICINGBYDESC

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTPRICINGBYDESC

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTPRICINGBYDESC

Product

Product

  • Must be a valid producing product for Facility.

MMCONTRACTPRICINGBYDESC

Contract Description

Contract Description

  • Maximum size of 60 characters.

MMCONTRACTPRICINGBYDESC

Price Code

Price Code

Options include:

  • DFLT (Default Price)

  • UNIT (Price Per Unit)

  • CONTRT (Total Contract Value)

  • ZERO (Zero Price)

MMCONTRACTPRICINGBYDESC

Input Price

Input Price

  • Maximum size of 9999.99999999 (4v8).

MMCONTRACTPRICINGBYDESC

Value

Contract Value

  • Optional. Only applicable when Price Code = CONTRT.

  • Maximum size of 999999999.99 (9v2).

MMCONTRACTPRICINGBYDESC

Transportation Type

Transportation Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICINGBYDESC

Transportation Rate/Value

Transportation Rate/Value

  • Optional. Only applicable when Transportation Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

MMCONTRACTPRICINGBYDESC

Quality Adj. Type

Quality Adjustment Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICINGBYDESC

Quality Adj. Cost

Quality Adjustment Rate/Value

  • Optional. Only applicable when Quality Adj. Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICINGBYDESC

Tariff Fee Type

Tariff Fee Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICINGBYDESC

Tariff Cost

Tariff Fee Rate/Value

  • Optional. Only applicable when Tariff Fee Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICINGBYDESC

Line Loss Type

Line Loss Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICINGBYDESC

Line Loss

Line Loss Rate/value

  • Optional. Only applicable when Line Loss Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICINGBYDESC

Other#1 Fee Type

Other#1 Fee Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICINGBYDESC

Other#1 Cost

Other#1 Fee Rate/Value

  • Optional. Only applicable when Other#1 Fee Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

MMCONTRACTPRICINGBYDESC

Other#2 Fee Type

Other#2 Fee Type

Options include:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount)

  • DFLT (Default Rate)

MMCONTRACTPRICINGBYDESC

Other#2 Cost

Other#2 Fee Rate/Value

  • Optional. Only applicable when Other#2 Fee Type is RATE or VALUE.

  • Maximum size of 99999999.99999 (8v5).

    • When Quality Adj. Type = VALUE, maximum size is 99999999.99 (8v2).

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates. There may be more than one market master facility purchaser contract with the same Contract Description; an error will be generated when more than one valid matching contract found.

Sample Data for MMCONTRACTPRICINGBYDESC Template

Production Date

Facility Type

Facility ID

Product

Contract Description

Price Code

Input Price

Value

Transportation Type

Transportation Rate/Value

Quality Adj. Type

Quality Adj. Cost

Tariff Fee Type

Tariff Cost

Line Loss Type

Line Loss

Other#1 Fee Type

Other#1 Cost

Other#2 Fee Type

Other#2 Cost

Production Date

Facility Type

Facility ID

Product

Contract Description

Price Code

Input Price

Value

Transportation Type

Transportation Rate/Value

Quality Adj. Type

Quality Adj. Cost

Tariff Fee Type

Tariff Cost

Line Loss Type

Line Loss

Other#1 Fee Type

Other#1 Cost

Other#2 Fee Type

Other#2 Cost

200804

B

RLTT9

OIL

RLT1

UNIT

251.15

0

DFLT

0

RATE

.56

NA

0

NA

0

VALUE

23.48

NA

0

200804

P

RLTCPNP1

GAS

RLT23

CONTRT

0

12000.25

NA

0

NA

0

RATE

.45

VALUE

250.10

NA

0

RATE

1.23

MMCONTRACTUNITPRICE

Template for MMCONTRACTUNITPRICE

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTUNITPRICE

Production Date

Production Date

  • Format YYYYMM.

MMCONTRACTUNITPRICE

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTUNITPRICE

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTUNITPRICE

Product

Product

  • Must be a valid producing product for Facility.

MMCONTRACTUNITPRICE

Disposition Type

Disposition Type

Options include:

  • DELV (Delivery)

  • XFER (Transfer)

  • INJ (Injection)

  • XI (Inventory Transfer)

  • LF (Return Consumption)

  • LF99 (Purchased Consumption)

  • XFRM (Transfer for Market)

  • XCONS (Transfer for Consumption)

  • XFUEL (Transfer for Fuel)

  • FIRE (Fire)

  • SPILL (Spill)

  • THEFT (Theft)

  • BLEND (Blending Shrinkage)

  • FS (Fuel Sale)

  • XP (Plant to Plant)

  • EX1 (Owner to Owner Transfer)

  • EX2 (Owner to Owner Sale)

MMCONTRACTUNITPRICE

Destination Type

Destination Type

  • Optional. Not all Disposition Types require a Destination (i.e., Fire, Theft).

Options include:

  • B (Battery)

  • D (Delivery System)

  • G (Gathering System)

  • I (Injection Facility)

  • P (Plant)

MMCONTRACTUNITPRICE

Destination ID

Destination ID

  • Unique identifier for Destination Facility or Delivery System.

  • Optional. Must be populated when Destination Type is populated.

MMCONTRACTUNITPRICE

Disposition Sequence

Disposition Sequence

  • Maximum size of 9999.

MMCONTRACTUNITPRICE

Allocation Number

Allocation Number

  • Maximum size of 99.

MMCONTRACTUNITPRICE

Purchaser Type

Purchaser Type

Options include:

  • PURCH (Purchaser)

  • XFER (Facility Transfer)

  • LOSS (Loss - Fire Theft Spill or Shrinkage)

  • DILGS (Dilution Gas)

  • RETFL (Netted Return Fuel)

MMCONTRACTUNITPRICE

Purchaser ID

Purchaser ID

  • Unique Identifier for Purchaser.

  • Optional. Must be populated when Purchaser Type = PURCH.

MMCONTRACTUNITPRICE

Purchaser Sequence

Purchaser Sequence

  • Maximum size of 99.

MMCONTRACTUNITPRICE

Input Price

Input Price

  • Maximum size of 9999.99999999 (4v8).

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates.

Sample Data for MMCONTRACTUNITPRICE Template

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

Input Price

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

Input Price

200804

B

RLTT9

OIL

DELV

D

7341O

0

2

PURCH

VEN1002

0

251.15

200804

B

RLTT9

OIL

DELV

D

7341O

0

3

PURCH

115874

0

245.88

MMCONTRACTUNITPRICEBYDESC

Template for MMCONTRACTUNITPRICEBYDESC

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTUNITPRICEBYDESC

Production Date

Production Date

Format YYYYMM.

MMCONTRACTUNITPRICEBYDESC

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTUNITPRICEBYDESC

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTUNITPRICEBYDESC

Product

Product

  • Must be a valid producing product for Facility.

MMCONTRACTUNITPRICEBYDESC

Contract Description

Contract Description

  • Maximum size of 60 characters.

MMCONTRACTUNITPRICEBYDESC

Input Price

Input Price

  • Maximum size of 9999.99999999 (4v8).

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates. There may be more than one market master facility purchaser contract with the same Contract Description; all valid matching contracts will be updated.

Sample Data for MMCONTRACTUNITPRICEBYDESC Template

Production Date

Facility Type

Facility ID

Product

Contract Description

Input Price

Production Date

Facility Type

Facility ID

Product

Contract Description

Input Price

200804

B

RLTT9

OIL

RLT1

251.15

200804

P

RLTCPNP1

GAS

RLT23

5.48

 

MMCONTRACTUSERINPUT (as of Release 23.2)

Template for MMCONTRACTINPUT

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTUSERINPUT

Production Date

Production Date

  • Format YYYYMM.

MMCONTRACTUSERINPUT

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTUSERINPUT

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTUSERINPUT

Product

Product

  • Must be a valid producing product for Facility.

MMCONTRACTUSERINPUT

Disposition Type

Disposition Type

Options include:

  • DELV (Delivery)

  • XFER (Transfer)

  • INJ (Injection)

  • XI (Inventory Transfer)

  • LF (Return Consumption)

  • LF99 (Purchased Consumption)

  • XFRM (Transfer for Market)

  • XCONS (Transfer for Consumption)

  • XFUEL (Transfer for Fuel)

  • FIRE (Fire)

  • SPILL (Spill)

  • THEFT (Theft)

  • BLEND (Blending Shrinkage)

  • FS (Fuel Sale)

  • XP (Plant to Plant)

  • EX1 (Owner to Owner Transfer)

  • EX2 (Owner to Owner Sale)

MMCONTRACTUSERINPUT

Destination Type

Destination Type

  • Optional. Not all Disposition Types require a Destination (i.e., Fire, Theft).

Options include:

  • B (Battery)

  • D (Delivery System)

  • G (Gathering System)

  • I (Injection Facility)

  • P (Plant)

MMCONTRACTUSERINPUT

Destination ID

Destination ID

  • Unique identifier for Destination Facility or Delivery System.

  • Optional. Must be populated when Destination Type is populated.

MMCONTRACTUSERINPUT

Disposition Sequence

Disposition Sequence

  • Maximum size of 9999.

MMCONTRACTUSERINPUT

Allocation Number

Allocation Number

  • Maximum size of 99.

MMCONTRACTUSERINPUT

Purchaser Type

Purchaser Type

Options include:

  • PURCH (Purchaser)

  • XFER (Facility Transfer)

  • LOSS (Loss - Fire Theft Spill or Shrinkage)

  • DILGS (Dilution Gas)

  • RETFL (Netted Return Fuel)

MMCONTRACTUSERINPUT

Purchaser ID

Purchaser ID

  • Unique Identifier for Purchaser.

  • Optional. Must be populated when Purchaser Type = PURCH.

MMCONTRACTUSERINPUT

Purchaser Sequence

Purchaser Sequence

  • Maximum size of 99.

MMCONTRACTUSERINPUT

User Input Volume

User Input Volume

  • Maximum size of 99999999.9 (8v1).

  • Cannot be negative.

MMCONTRACTUSERINPUT

Override Energy

Override Energy (GJs)

  • Product must be GAS or RAWGAS for Override Energy to be imported.

  • Maximum size of 999999999999 (12v0).

  • Cannot be negative.

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates. The contract must also have an Allocation Method of User Input.

Sample Data for MMCONTRACTUSERINPUT Template

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

User Input Volume

Override Energy (GJs)

Production Date

Facility Type

Facility ID

Product

Disposition Type

Destination Type

Destination ID

Disposition Sequence

Allocation Number

Purchaser Type

Purchaser ID

Purchaser Sequence

User Input Volume

Override Energy (GJs)

200804

P

RLTCPNP1

GAS

DELV

D

ALLIAD

0

2

PURCH

VEN1002

0

550.2

15245

200804

P

RLTCPNP1

C3

DELV

D

00015D

0

0

PURCH

VEN2002

0

50.2

0

MMCONTRACTUSERINPUTBYDESC (as of Release 23.2)

Template for MMCONTRACTUSERINPUTBYDESC

Template ID

Column Header

Description

Template ID

Column Header

Description

MMCONTRACTUSERINPUTBYDESC

Production Date

Production Date

Format YYYYMM.

MMCONTRACTUSERINPUTBYDESC

Facility Type

Facility Type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

MMCONTRACTUSERINPUTBYDESC

Facility

Facility

  • Unique identifier for Facility.

MMCONTRACTUSERINPUTBYDESC

Product

Product

  • Must be a valid producing product for Facility.

MMCONTRACTUSERINPUTBYDESC

Contract Description

Contract Description

  • Maximum size of 60 characters.

MMCONTRACTUSERINPUTBYDESC

User Input Volume

User Input Volume

  • Maximum size of 99999999.9 (8v1)

  • Cannot be negative.

MMCONTRACTUSERINPUTBYDESC

Override Energy

Override Energy (GJs)

  • Product must be GAS or RAWGAS for Override Energy to be imported.

  • Maximum size of 999999999999 (12v0).

  • Cannot be negative.

Note: This is an update only template. The market master facility purchaser contract must have already been created in Qbyte Metrix prior to importing any updates. The contract must also have an Allocation Method of User Input. There may be more than one market master facility purchaser contract with the same Contract Description; an error will be generated when more than one valid matching contract found.

Sample Data for MMCONTRACTUSERINPUTBYDESC Template

Production Date

Facility Type

Facility ID

Product

Contract Description

User Input Volume

Override Energy (GJs)

Production Date

Facility Type

Facility ID

Product

Contract Description

User Input Volume

Override Energy (GJs)

200804

P

RLTCPNP1

GAS

RLT23

554.2

16248

200804

P

RLTCPNP1

C3

RLTIMP

22.3

0

 

OBLIGATIONFACTORVALUE

Template for OBLIGATIONFACTORVALUE

Template ID

Column Header

Description

Template ID

Column Header

Description

OBLIGATIONFACTORVALUE

Production Date

Format YYYYMM.

OBLIGATIONFACTORVALUE

Well/Tract Type

Well/tract type

Options include:

  • W (Well)

  • T (Tract)

OBLIGATIONFACTORVALUE

Well/Tract

Unique identifier for Well or Tract.

OBLIGATIONFACTORVALUE

Product

Must be a valid product for Royalty Obligations.

OBLIGATIONFACTORVALUE

Obligation Number

A four-character field that must contain only digits typically containing several zeros (i.e., 0001).

OBLIGATIONFACTORVALUE

Obligation Factor ID

Factor ID

  • Maximum 16 characters.

  • Must be a Royalty Obligation factor.

OBLIGATIONFACTORVALUE

Required

Required flag with valid options of Y or N.

OBLIGATIONFACTORVALUE

Factor Value

Maximum size of 9999999999.99999999 (10v8).

OBLIGATIONFACTORVALUE

Global Factor ID

Factor ID

  • Maximum 16 characters.

  • Must be a Royalty Global factor.

Sample Data for OBLIGATIONFACTORVALUE

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Obligation Factor ID

Required

Factor Value

Global Factor ID

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Obligation Factor ID

Required

Factor Value

Global Factor ID

201407

W

ATESTB01W02

GAS

0001

ACHROYRATE2

Y

0.25



201407

W

03/07-17-123-05W6/0

BYP

1234

ACHROYRATE2

N

0

AKEROYFAC01

201407

T

UHOL2TRACT1

OIL

0002

ACHROYRATE2

Y

25.3



 

Royalty Obligation Factor Values After Importing - OBLIGATIONFACTORVALUE

OILVALUATIONTRANS

Template for OILVALUATIONTRANS

Template ID

Column Header

Description

Template ID

Column Header

Description

OILVALUATIONTRANS

Production Date

Format YYYYMM.

OILVALUATIONTRANS

Submitting Facility

Submitting facility

  • Petrinex formatted identifier with or without spaces (i.e., SKBT0058723 or SK BT 0058723).

OILVALUATIONTRANS

Delivering Facility

Delivering facility

  • Petrinex formatted identifier with or without spaces (i.e., SKBT0058723 or SK BT 0058723).

OILVALUATIONTRANS

Receiving Facility

Receiving facility

  • Petrinex formatted identifier with or without spaces (i.e., SKBT0058723 or SK BT 0058723).

OILVALUATIONTRANS

Custody Transfer Facility

Custody transfer facility

  • Petrinex formatted identifier with or without spaces (i.e., SKBT0058723 or SK BT 0058723).

OILVALUATIONTRANS

Transportation Rate

Transportation Rate

Must be greater than or equal to 0. Maximum size of 9999.99999 (4v5).

Valid for submitting facilities in AB, MB, and SK for any production date and for submitting facilities in BC prior to the BC Valuation Changes 2024 Implementation date as set in System Configuration - Function Implementation.

OILVALUATIONTRANS

Default Transportation Type

 

(available as of Release 24.2)

Default Transportation Type for any Transportation coming from Pricing data.

Options are:

  • TRANSPPL (Transportation - Pipeline)

  • TRANSRL (Transportation - Rail)

  • TRANSTRK (Transportation - Truck

Only valid for BC submitting facilities and production dates on or after the BC Valuation Changes 2024 Implementation date as set in System Configuration - Function Implementation. For prior dates it will be ignored and default to TRANSPPL.

  • Note: As of August 2024, the BC government has delayed the implementation of the BC Valuation Changes 2024, indicating that they now believe this will not be implemented until 2027.

OILVALUATIONTRANS

Quality Adjustment Rate

(available as of Release 24.2)

Quality Adjustment Rate

Maximum size of 99999999.99 (8v2).

Only valid for BC submitting facilities and production dates on or after the BC Valuation Changes 2024 Implementation date as set in System Configuration - Function Implementation.

  • Note: As of August 2024, the BC government has delayed the implementation of the BC Valuation Changes 2024, indicating that they now believe this will not be implemented until 2027.

OILVALUATIONTRANS

Transportation Pipeline Rate

(available as of Release 24.2)

Transportation Pipeline Rate

Maximum size of 99999999.99 (8v2).

Only valid for BC submitting facilities and production dates on or after the BC Valuation Changes 2024 Implementation date as set in System Configuration - Function Implementation.

  • Note: As of August 2024, the BC government has delayed the implementation of the BC Valuation Changes 2024, indicating that they now believe this will not be implemented until 2027.

OILVALUATIONTRANS

Transportation Rail Rate

(available as of Release 24.2)

Transportation Rail Rate

Maximum size of 99999999.99 (8v2).

Only valid for BC submitting facilities and production dates on or after the BC Valuation Changes 2024 Implementation date as set in System Configuration - Function Implementation.

  • Note: As of August 2024, the BC government has delayed the implementation of the BC Valuation Changes 2024, indicating that they now believe this will not be implemented until 2027.

OILVALUATIONTRANS

Transportation Truck Rate

(available as of Release 24.2)

Transportation Truck Rate

Maximum size of 99999999.99 (8v2).

Only valid for BC submitting facilities and production dates on or after the BC Valuation Changes 2024 Implementation date as set in System Configuration - Function Implementation.

  • Note: As of August 2024, the BC government has delayed the implementation of the BC Valuation Changes 2024, indicating that they now believe this will not be implemented until 2027.

Note: This is an update only template; the Transportation Rate, Default Transportation Type, Quality Adjustment Rate, Transportation Pipeline Rate, Transportation Rail Rate, and Transportation Truck Rate are the only columns that can be updated. 

Sample Data for OILVALUATIONTRANS Template

Production Date

Submitting Facility

Delivering Facility

Receiving Facility

Custody Transfer Facility

Transportation Rate

Default Transportation Type

Quality Adjustment Rate

Transportation Pipeline Rate

Transportation Rail Rate

Transportation Truck Rate

Production Date

Submitting Facility

Delivering Facility

Receiving Facility

Custody Transfer Facility

Transportation Rate

Default Transportation Type

Quality Adjustment Rate

Transportation Pipeline Rate

Transportation Rail Rate

Transportation Truck Rate

201406

SKBTS4L7436



SKBTB4L3983

SKTMTT17008

3.31000

 

 

 

 

 

201406

SKBTB4M3639



SKPLOP00017

SKPLOP00017

2.93000

 

 

 

 

 

201406

SKUNU6113

SKBTB4L3991

SKBTB4L3926

SKPLOP00017

7.63001

 

 

 

 

 

202409

BCBT0006550



BCBT0006589

BCPL0009879

0.00000

TRANSPPL

-0.26

1.02

0.00

0.00

OWNERGOVTCODEUPD (as of Release 23.4)

Template for OWNERGOVTCODEUPD

Template ID

Column Header

Description

Template ID

Column Header

Description

OWNERGOVTCODEUPD

Production Date

Format YYYYMM.

OWNERGOVTCODEUPD

Owner ID

Owner ID

  • Maximum 16 characters.

OWNERGOVTCODEUPD

AB Government Code

Alberta Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Alberta government code will be deleted.

OWNERGOVTCODEUPD

BC Government Code

British Columbia Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous British Columbia government code will be deleted.

OWNERGOVTCODEUPD

MB Government Code

Manitoba Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Manitoba government code will be deleted.

OWNERGOVTCODEUPD

ON Government Code

Ontario Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Ontario government code will be deleted.

OWNERGOVTCODEUPD

SK Government Code

Saskatchewan Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Saskatchewan government code will be deleted.

OWNERGOVTCODEUPD

Federal Government Code

Federal Government Code (used for IOGC reporting).

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Federal government code will be deleted.

Sample Data for  OWNERGOVTCODEUPD Template

Production Date

Owner ID

AB Government Code

BC Government Code

MB Government Code

ON Government Code

SK Government Code

Federal Government Code

Production Date

Owner ID

AB Government Code

BC Government Code

MB Government Code

ON Government Code

SK Government Code

Federal Government Code

201407

RLT006

AR06

BR06









201407

RLT007

!

!

MR07

!

!

!

OWNERMASTER (as of Release 23.4)

Template for OWNERMASTER

Template ID

Column Header

Description

Template ID

Column Header

Description

OWNERMASTER

Production Date

Format YYYYMM.

OWNERMASTER

Owner ID

Owner ID

  • Maximum 16 characters.

OWNERMASTER

Owner Name

Owner Name

  • Maximum of 40 characters.

OWNERMASTER

Address Line#1

Address Line #1

Optional.

  • Maximum of 30 characters.

OWNERMASTER

Address Line#2

Address Line #2

Optional.

  • Maximum of 30 characters.

OWNERMASTER

Address Line#3

Address Line #3

Optional.

  • Maximum of 30 characters.

OWNERMASTER

Address Line#4

Address Line #4

Optional.

  • Maximum of 30 characters.

OWNERMASTER

Postal Code

Postal Code

Optional.

  • Maximum of 12 characters.

OWNERMASTER

Phone Number

Phone Number

Optional.

  • Maximum of 12 characters.

OWNERMASTER

Fax Number

Fax Number

Optional.

  • Maximum of 12 characters.

OWNERMASTER

Contact Name

Contact Name

Optional.

  • Maximum of 60 characters.

OWNERMASTER

User Defined#1

User Defined#1

Optional.

  • Maximum of 16 characters.

NOTE: This field may be mandatory depending upon system User Defined Labels for OwnerMaster.userDefined1.

OWNERMASTER

NRT Applicable

NRT Applicable

Options are:

  • Y - Yes

  • N - No

OWNERMASTER

NRT Rate Override

NRT Rate Override

  • Must be 0 when NRT Applicable is No.

  • Must be between 0 and 99.999 when NRT Applicable is Yes.

  • Maximum size of 999.999 (3v3).

OWNERMASTER

JIBLink Province

JIBLink Province

Optional.

  • Maximum of 2 characters.

OWNERMASTER

JIBLink Country

JIBLink Country

Optional.

  • Maximum of 2 characters.

OWNERMASTER

BC Reporting/RTP Override

BC Reporting/RTP Override Owner

Optional.

  • Must be blank when the owner being updated is a Region Master Owner.

  • Must have a valid Owner Master for the production date.

  • Cannot be an owner that is Inactive.

  • Cannot be the same as the owner being updated.

  • Cannot be an owner that, itself, has a BC Reporting/RTP Override owner for the production date.

  • Maximum of 16 characters.

OWNERMASTER

Global Obligation Payor

Global Obligation Payor

Options are:

  • Y - Yes

  • N - No

Note: This field will be ignored when the system Function Implementation option Enable the use of Global Obligation Payors is not active for the production date, but if entered it must still pass data type validations. This means it must be Y, N, !, or blank.

OWNERMASTER

AB Government Code

Alberta Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Alberta government code will be deleted.

OWNERMASTER

BC Government Code

British Columbia Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous British Columbia government code will be deleted.

OWNERMASTER

MB Government Code

Manitoba Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Manitoba government code will be deleted.

OWNERMASTER

ON Government Code

Ontario Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Ontario government code will be deleted.

OWNERMASTER

SK Government Code

Saskatchewan Government Code.

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Saskatchewan government code will be deleted.

OWNERMASTER

Federal Government Code

Federal Government Code (used for IOGC reporting).

Optional.

  • Maximum of 30 characters.

Note: Use an ! in this column to leave the government code as is. If left blank, then any previous Federal government code will be deleted.

OWNERMASTER

Note Text

Owner Note

Optional.

  • Maximum of 4000 characters.

Sample Data for  OWNERMASTER Template

Production Date

Owner ID

Owner Name

Address Line#1

Address Line#2

Address Line#3

Address Line#4

Postal Code

Phone Number

Fax Number

Contact Name

User Defined#1

NRT Applicable

NRT Rate Override

JIBLink Province

JIBLink Country

BC Reporting/RTP Owner

Global Obligation Payor

AB Government Code

BC Government Code

MB Government Code

ON Government Code

SK Government Code

Federal Government Code

Note Text

Production Date

Owner ID

Owner Name

Address Line#1

Address Line#2

Address Line#3

Address Line#4

Postal Code

Phone Number

Fax Number

Contact Name

User Defined#1

NRT Applicable

NRT Rate Override

JIBLink Province

JIBLink Country

BC Reporting/RTP Owner

Global Obligation Payor

AB Government Code

BC Government Code

MB Government Code

ON Government Code

SK Government Code

Federal Government Code

Note Text

201407

RLT006

RLT Owner 6

301, 7648 5th St. S.W.

Calgary, Alberta

Canada



T2X7Y3

403-555-5555





006RLT

N

00.000







N

AR06

BR06

MR06



SR06

FR06

Added owner for a new WIO.

201407

RLT007

!

!

!

!

!

!

!

!

!

007RLT

Y

7.5

!

!

!

!

!

!

!

!

!

!

Updated User Defined and set NRT correctly.

 

OWNERNAMEADDRESSUPD (as of Release 23.4)

Template for OWNERNAMEADDRESSUPD

Template ID

Column Header

Description

Template ID

Column Header

Description

OWNERNAMEADDRESSUPD

Production Date

Format YYYYMM.

OWNERNAMEADDRESSUPD

Owner ID

Owner ID

  • Maximum 16 characters.

OWNERNAMEADDRESSUPD

Owner Name

Owner Name

  • Maximum of 40 characters.

OWNERNAMEADDRESSUPD

Address Line#1

Address Line #1

Optional.

  • Maximum of 30 characters.

OWNERNAMEADDRESSUPD

Address Line#2

Address Line #2

Optional.

  • Maximum of 30 characters.

OWNERNAMEADDRESSUPD

Address Line#3

Address Line #3

Optional.

  • Maximum of 30 characters.

OWNERNAMEADDRESSUPD

Address Line#4

Address Line #4

Optional.

  • Maximum of 30 characters.

OWNERNAMEADDRESSUPD

Postal Code

Postal Code

Optional.

  • Maximum of 30 characters.

Sample Data for  OWNERNAMEADDRESSUPD Template

Production Date

Owner ID

Owner Name

Address Line#1

Address Line#2

Address Line#3

Address Line#4

Postal Code

Production Date

Owner ID

Owner Name

Address Line#1

Address Line#2

Address Line#3

Address Line#4

Postal Code

201407

RLT006

RLT Owner 6

301, 7648 5th St. S.W.

Calgary, Alberta

Canada



T2X7Y3

201407

RLT007

!

511, 748 8th Ave. S.W.

!

!



!

 

PARTNEROPPRICING (as of Release 24.3)

Template for PARTNEROPPRICING

Template ID

Column Header

Description

Template ID

Column Header

Description

PARTNEROPPRICING

Production Date

Format YYYYMM.

PARTNEROPPRICING

Battery

Unique Identifier for the Partner Operated Battery.

PARTNEROPPRICING

Transaction Type

Options are:

  • CRWN (Crown)

  • FRHD (Freehold)

  • ORR (Override)

  • REV (Sales)

PARTNEROPPRICING

Product

Must be a valid producing product for Partner Operated.

PARTNEROPPRICING

Plant

Optional. Unique Identifier for a Plant.

  • Only valid for Sales (REV) transactions when Product is not Oil.

PARTNEROPPRICING

Purchaser/Royalty Owner ID

Unique Identifier for an Owner. Only valid for Sales (REV) transactions.

  • Maximum 16 characters.

PARTNEROPPRICING

Purchaser Sequence

Optional.

  • Only valid for Sales (REV) transactions.

  • If entered, must be greater than or equal to 0 and a maximum size of 99 (2).

PARTNEROPPRICING

Destination Type

Optional.

  • Only valid for Sales (REV) transactions.

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

  • D (Delivery System)

  • I (Injection Facility)

PARTNEROPPRICING

Destination

Optional. Unique Identifier for the Destination.

  • Only valid for Sales (REV) transactions when Destination Type is not blank.

PARTNEROPPRICING

Pricing UDF1

Optional.

  • Maximum size of 16 characters.

  • May be mandatory based on Corporate setting of PartnerOpBatteryPrice.userDefined1 (PARTOPPRICEUSERDEFINED1).

PARTNEROPPRICING

Shipper Owner Contract

Optional.

  • Maximum size of 60 characters.

  • Only valid for Sales (REV) transactions when Product is Oil and province has implemented Oil Valuation RTP.

PARTNEROPPRICING

Pricing Option

Options are:

  • CONTRT (Total Contract Value)

  • UNIT (Price Per Unit)

PARTNEROPPRICING

Allocate By

Optional.

  • Only valid for Gas Sales (REV) transactions.

Options are:

  • GJ (Gigajoules)

  • SALE (Sales Volume).

PARTNEROPPRICING

Price/Value

Optional.

  • When Pricing Option is CONTRT (Total Contract Value) maximum size is 999999999.99 (9v2).

  • When Pricing Option is UNIT (Price Per Unit) maximum size is 9999.99999999 (4v8).

  • If left blank, it will be set to 0.

PARTNEROPPRICING

Transportation Type

Optional.

  • Only valid for Sales (REV) transactions.

Options are:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount).

PARTNEROPPRICING

Transportation Rate/Value

Optional.

  • Only valid for Sales (REV) transactions when Transportation Type is not NA.

  • When Transportation Type is RATE (Rate) maximum size is 9999.99999999 (4v8).

  • When Transportation Type is VALUE (Total Amount) maximum size is 999999999.99 (9v2).

PARTNEROPPRICING

Quality Adjustment Type

Optional.

  • Only valid for Sales (REV) transactions.

Options are:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount).

PARTNEROPPRICING

Quality Adjustment Rate/Value

Optional.

  • Only valid for Sales (REV) transactions when Quality Adjustment Type is not NA.

  • When Quality Adjustment Type is RATE (Rate) maximum size is 9999.99999999 (4v8).

  • When Quality Adjustment Type is VALUE (Total Amount) maximum size is 999999999.99 (9v2).

PARTNEROPPRICING

Tariff Type

Optional.

  • Only valid for Sales (REV) transactions.

Options are:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount).

PARTNEROPPRICING

Tariff Rate/Value

Optional.

  • Only valid for Sales (REV) transactions when Tariff Type is not NA.

  • When Tariff Type is RATE (Rate) maximum size is 9999.99999999 (4v8).

  • When Tariff Type is VALUE (Total Amount) maximum size is 999999999.99 (9v2).

PARTNEROPPRICING

Line Loss Type

Optional.

  • Only valid for Sales (REV) transactions.

Options are:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount).

PARTNEROPPRICING

Line Loss Rate/Value

Optional.

  • Only valid for Sales (REV) transactions when Line Loss Type is not NA.

  • When Line Loss Type is RATE (Rate) maximum size is 9999.99999999 (4v8).

  • When Line Loss Type is VALUE (Total Amount) maximum size is 999999999.99 (9v2).

PARTNEROPPRICING

Other#1 Type

Optional.

  • Only valid for Sales (REV) transactions.

Options are:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount).

PARTNEROPPRICING

Other#1 Rate/Value

Optional.

  • Only valid for Sales (REV) transactions when Other#1 Type is not NA.

  • When Other#1 Type is RATE (Rate) maximum size is 9999.99999999 (4v8).

  • When Other#1 Type is VALUE (Total Amount) maximum size is 999999999.99 (9v2).

PARTNEROPPRICING

Other#2 Type

Optional.

  • Only valid for Sales (REV) transactions.

Options are:

  • NA (Not Applicable)

  • RATE (Rate)

  • VALUE (Total Amount).

PARTNEROPPRICING

Other#2 Rate/Value

Optional.

  • Only valid for Sales (REV) transactions when Other#2 Type is not NA.

  • When Other#2 Type is RATE (Rate) maximum size is 9999.99999999 (4v8).

  • When Other#2 Type is VALUE (Total Amount) maximum size is 999999999.99 (9v2).

Sample Data for PARTOPPRICING Template

Production Date

Battery

Transaction Type

Product

Plant

Purchaser/Royalty Owner ID

Purchaser Sequence

Destination Type

Destination

Pricing UDF1

Shipper Owner Contract

Pricing Option

Allocate By

Price/Value

Transportation Type

Transportation Rate/Value

Quality Adjustment Type

Quality Adjustment Rate/Value

Tariff Type

Tariff Rate/Value

Line Loss Type

Line Loss Rate/Value

Other#1 Type

Other#1 Rate/Value

Other#2 Type

Other#2 Rate/Value

Production Date

Battery

Transaction Type

Product

Plant

Purchaser/Royalty Owner ID

Purchaser Sequence

Destination Type

Destination

Pricing UDF1

Shipper Owner Contract

Pricing Option

Allocate By

Price/Value

Transportation Type

Transportation Rate/Value

Quality Adjustment Type

Quality Adjustment Rate/Value

Tariff Type

Tariff Rate/Value

Line Loss Type

Line Loss Rate/Value

Other#1 Type

Other#1 Rate/Value

Other#2 Type

Other#2 Rate/Value

201407

AKEABPARTOP

REV

C3MX

OF131281

000023

0

 

 

 

 

UNIT

SALE

85.49254

NA

0

NA

0

NA

0

NA

0

NA

0

NA

0

201407

AKEABPARTOP

REV

C3SP

 

000012

0

D

0000957

 

 

CONTRT

SALE

15487.35

RATE

5.4864

NA

0

NA

0

NA

0

NA

0

NA

0

201407

AKEABPARTOP

 

GAS

OF0001121

000012

0

D

DEL_POP

 

 

UNIT

GJ

6.857

NA

0

NA

0

RATE

.58

NA

0

NA

0

NA

0

201407

AKEABPARTOP

 

OIL

 

000021

0

 

 

 

CONT234

UNIT

SALE

500.487568

RATE

15.4876

RATE

-1.254

NA

0

NA

0

NA

0

NA

0

PARTNEROPSALES

Template for PARTNEROPSALES

Template ID

Column Header

Description

Template ID

Column Header

Description

PARTNEROPSALES

Production Date

Format YYYYMM.

PARTNEROPSALES

Battery

Unique Identifier for the Battery the well is attached to.

PARTNEROPSALES

Well

Unique identifier for a Well.

PARTNEROPSALES

Product

Must be a valid producing product for Facility.

PARTNEROPSALES

Purchaser

Unique Identifier for Purchaser

  • Maximum 16 characters.

PARTNEROPSALES

Purchaser Sequence

Must be greater than or equal to 0 and a maximum size of 99 (2).

PARTNEROPSALES

Facility Type

Facility type

Options include:

  • P (Plant)

Note: This can be left blank if the Facility ID is blank.

PARTNEROPSALES

Facility

Unique Identifier for Facility. Can be left blank.

PARTNEROPSALES

Destination Type

Destination type

Options include:

  • B (Battery)

  • G (Gathering System)

  • P (Plant)

  • D (Delivery System)

  • I (Injection)

  • blank (Not applicable)

PARTNEROPSALES

Destination

Unique Identifier for Destination.

Note: This can be left blank if the Destination Type is blank.

PARTNEROPSALES

Net Volume

Maximum size of 99999999.9 (8v1)

PARTNEROPSALES

Net Value

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Net GJs

Maximum size of 999999999999 (12)

PARTNEROPSALES

Net Trans.

Net Transportation Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Net Quality Adj.

Net Quality Adjustment Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Net Tariff

Net Tariff Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Net Line Loss

Net Line Loss Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Net Other#1

Net Other#1 Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Net Other#2

Net Other#2 Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross Volume

Maximum size of 99999999.9 (8v1)

PARTNEROPSALES

Gross Value

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross GJs

Maximum size of 999999999999 (12)

PARTNEROPSALES

Gross Trans.

Gross Transportation Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross Quality Adj.

Gross Quality Adjustment Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross Tariff

Gross Tariff Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross Line Loss

Gross Line Loss Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross Other#1

Gross Other#1 Value.

Maximum size of 999999999.99 (9v2)

PARTNEROPSALES

Gross Other#2

Gross Other#2 Value.

Maximum size of 999999999.99 (9v2)

Note: This is an update only Template. The following columns are the only columns that can be updated using this template. Updating these columns is conditional to the Transaction Level (Gross Input, Net Input or Gross and Net Input) of the Partner Operated battery:

  • Net Volume, Value, GJs, Transportation, Quality Adjustment, Tariff, Line Loss, Other#1, and Other#2 .

  • Gross Volume, Value, GJs,  Transportation, Quality Adjustment, Tariff, Line Loss, Other#1, and Other#2

Sample Data for PARTNEROPSALES Template

Production Date

Battery

Well

Product

Purchaser

Purchaser Sequence

Facility Type

Facility

Destination Type

Destination

Net Volume

Net Value

Net GJs

Net Trans.

Net Quality Adj.

Net Tariff

Net Line Loss

Net Other#1

Net Other#2

Gross Volume

Gross Value

Gross GJs

Gross Trans.

Gross Quality Adj.

Gross Tariff

Gross Line Loss

Gross Other#1

Gross Other#2

Production Date

Battery

Well

Product

Purchaser

Purchaser Sequence

Facility Type

Facility

Destination Type

Destination

Net Volume

Net Value

Net GJs

Net Trans.

Net Quality Adj.

Net Tariff

Net Line Loss

Net Other#1

Net Other#2

Gross Volume

Gross Value

Gross GJs

Gross Trans.

Gross Quality Adj.

Gross Tariff

Gross Line Loss

Gross Other#1

Gross Other#2

201407

AKEABPARTOP

AKEABPARTOPW02

C3MX

000023

0

P

OF131281





12.5

2230.63











15.62



23.4

4175.73











29.25



201407

AKEABPARTOP

AKEABPARTOPW02

C3SP

000012

0





D

0000957

1.4

630.17















2.8

1260.34















201407

AKEABPARTOP

AKEABPARTOPW02

C4

000012

0





D

0000957

1.5

1337.24













7.50

3.1

395.13













15.50

201407

AKEABPARTOP

AKEABPARTOPW02

C5

000012

0





D

0000957

0.6

161.93















1.1

296.88















201407

AKEABPARTOP

AKEABPARTOPW02

GAS

000012

0

P

OF0001121

D

DEL_POP

16.0

2072.00

592





148.00







20.0

2590.00

740





185.00







201407

AKEABPARTOP

AKEABPARTOPW02

GAS

000012

0





D

0002229

12.0

1716.00

520







0.25





24.1

3445.2

1044







0.50





201407

AKEABPARTOP

AKEABPARTOPW02

GAS

000022

0









22.0

4802.6

814













25.0

5457.5

925













201407

AKEABPARTOP

AKEABPARTOPW02

OIL

000001

0









32.7

9834.20



20.00

16.35









33.5

10074.79



20.49

16.75









201407

AKEABPARTOP

AKEABPARTOPW02

OIL

000021

0









43.4

13052.12



22.00

21.70









44.2

13292.71



22.40

22.10









ROYALTYGLOBALFACTOR

Template for ROYALTYGLOBALFACTOR

Template ID

Column Header

Description

Template ID

Column Header

Description

ROYALTYGLOBALFACTOR

Production Date

Format YYYYMM.

ROYALTYGLOBALFACTOR

Factor ID

Factor I

  • Maximum 16 characters.

ROYALTYGLOBALFACTOR

Description

Description

  • Maximum 40 characters.

ROYALTYGLOBALFACTOR

Factor Value

Maximum size of 9999999999.99999999 (10v8)

 

Sample Data for ROYALTYGLOBALFACTOR Template

Production Date

Factor ID

Description

Factor Value

Production Date

Factor ID

Description

Factor Value

201406

AKEROYFAC01

Royalty Factor Rate = 5.1

5.1

201405

AKEROYFAC01

!

5.2

201404

AKEROYFAC01

Royalty Factor Rate = 5.12345678

5.12345678

201406

AKEROYFAC02

Royalty Factor Rate = 5.456

5.456

201405

AKEROYFAC01

Royalty Factor Rate = 6.456

6.456

201404

AKEROYFAC01

Royalty Factor Rate = 7.456

7.456

 

Royalty Global Factors After Importing - ROYALTYGLOBALFACTOR

ROYALTYOBLIGATION

Template for ROYALTYOBLIGATION

Template ID

Column Header

Description

Template ID

Column Header

Description

ROYALTYOBLIGATION

Production Date

Format YYYYMM.

ROYALTYOBLIGATION

Well/Tract Type

Well/tract type

Options include:

  • W (Well)

  • T (Tract)

ROYALTYOBLIGATION

Well/Tract

Unique identifier for well or tract.

ROYALTYOBLIGATION

Product

Must be a valid product for Royalty Obligations.

ROYALTYOBLIGATION

Obligation Number

A four-character field that must contain only digits that typically contain several zeros (i.e., 0001).

ROYALTYOBLIGATION

Royalty Type

Indicates the type of obligation.

Options include:

  • CRWN (Crown)

  • FCLS (F-Class)

  • FRHD (Freehold)

  • IOGC (IOGC)

  • ORR (Override)

  • OTHER (Other)

ROYALTYOBLIGATION

Royalty Owner ID

Unique Identifier for Royalty Owner.

  • Maximum 16 characters.

ROYALTYOBLIGATION

Active

Indicates the Active status of the obligation. 

Options include:

  • Y (Active)

  • N (Inactive)

  • P (Pending)

  • E (Expired)

ROYALTYOBLIGATION

Taken In Kind

Indicates whether the Royalty Owner Takes In-Kind or not.

Options include:

  • Y (Yes)

  • N (No)

ROYALTYOBLIGATION

Tax Type

Indicates the Tax Type for the obligation. 

Options include:

  • EXEM (Exempt)

  • PROD (Production)

  • RESO (Resource)

ROYALTYOBLIGATION

Formula ID

Indicates the Royalty Formula ID to be used when calculating the obligation.

  • Can be blank if Active = P or E.

  • Maximum 16 characters.

ROYALTYOBLIGATION

Payment Type

Options include:

  • INCOME (Royalty Income)

  • OTHER (Paid On Our Behalf)

  • SELF (Paid By Self)

  • TIK (Take In Kind)

ROYALTYOBLIGATION

Payor Type

Indicates whether the payors are determined by Obligation or are Global

Options include:

  • OBLG (Obligation Level)

  • GLBL (Global Level)

ROYALTYOBLIGATION

DOI Extension ID

Indicates the DOI Extension number to be used for the obligation. 

  • If Default DOI, leave as blank.

  • Maximum 2 digits.

ROYALTYOBLIGATION

Paid By Owner ID

When the obligation is Paid On Our Behalf this indicates the owner paying the Royalty Obligation for us. 

  • Maximum 16 characters.

ROYALTYOBLIGATION

User Defined 1

Generic User-Defined field available to capture miscellaneous data. 

  • Maximum 16 characters.

ROYALTYOBLIGATION

User Defined 2

Generic User-Defined field available to capture miscellaneous data. 

  • Maximum 16 characters.

ROYALTYOBLIGATION

User Defined 3

Generic User-Defined field available to capture miscellaneous data. 

  • Maximum 16 characters.

ROYALTYOBLIGATION

Note

  • Maximum 4000 characters.

 

Sample Data for ROYALTYOBLIGATION Template

By Qbyte Metrix Well ID/Tract ID:

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Royalty Type

Royalty Owner ID

Active

Taken In Kind

Tax Type

Formula ID

Payment Type

Payor Type

DOI Extension ID

Paid By Owner ID

User Defined 1

User Defined 2

User Defined 3

Notes

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Royalty Type

Royalty Owner ID

Active

Taken In Kind

Tax Type

Formula ID

Payment Type

Payor Type

DOI Extension ID

Paid By Owner ID

User Defined 1

User Defined 2

User Defined 3

Notes

201405

W

ATESTB01W02

OIL

0003

FRHD

900001

Y

Y

EXEM

TIKF2

TIK

OBLG

10







UD 301

DOI R RI

201405

W

ATESTB01W02

GAS

0004

ORR

900002

!

!

!

!

!

!

!

!

Change

!

!

update

201405

W

ATESTB01W02

BYP

0005

ORR

900003

Y

N

EXEM

RLTSALES

SELF

OBLG





UD102



UD 303



201405

W

ATESTB01W02

OIL

0006

FRHD

900001

N

Y

EXEM

TLOROY02

TIK

OBLG





UD102

UD201

UD 304

IActive RI

201405

W

ATESTB01W02

GAS

0007

ORR

900002

E

N

EXEM

ROYWELL1

SELF

OBLG

12





UD202

UD 305

Expired RI

201405

W

ATESTB01W02

BYP

0008

ORR

900003

N

N

EXEM

RLTSALES

OTHER

OBLG



000001



UD203

UD 306



201405

W

ATESTB01W02

GAS

0009

ORR

900004

P

N

EXEM



SELF

GLBL







UD204

UD 307

Pen RI

201405

T

UHOLTRACT2

OIL

0001

FRHD

900001

Y

N

EXEM

RLTSALES

SELF

OBLG







UDT201





201405

T

UHOLTRACT2

GAS

0002

FRHD

900002

Y

N

EXEM

TLOROY02

OTHER

OBLG



000001



UDT202





201405

T

UHOLTRACT2

BYP

0003

FRHD

900003

N

N

EXEM

TLOROY02

SELF

OBLG







UDT203





201405

T

UHOLTRACT3

BYP

0001

FRHD

900003

N

N

EXEM

TLOROY02

SELF

OBLG







UDT301





 

Royalty Obligations After Importing - ROYALTYOBLIGATION

A note will always be created by the process to indicate that the obligation was Imported by Template. If you had a note entered on the template for that obligation, it will be created as a second note.

 

ROYALTYOBLIGATIONDELETE

Template for ROYALTYOBLIGATIONDELETE.

Template ID

Column Header

Description

Template ID

Column Header

Description

ROYALTYOBLIGATIONDELETE

Production Date

Format YYYYMM.

ROYALTYOBLIGATIONDELETE

Well/Tract Type

Well/tract type

Options include:

  • W (Well)

  • T (Tract)

ROYALTYOBLIGATIONDELETE

Well/Tract

Unique identifier for well or tract.

ROYALTYOBLIGATIONDELETE

Product

Must be a valid product for Royalty Obligations.

ROYALTYOBLIGATIONDELETE

Obligation Number

A four-character field that must contain only digits that typically contain several zeros (i.e., 0001).

Sample Data for ROYALTYOBLIGATIONDELETE Template

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

201405

W

ATESTB01W02

OIL

0003

201405

W

ATESTB01W02

BYP

0008

201405

W

ATESTB01W02

GAS

0009

201405

T

UHOLTRACT2

OIL

0001

201405

T

UHOLTRACT3

BYP

0001

 

ROYALTYOBLIGATIONFACTOR

Template for ROYALTYOBLIGATIONFACTOR

Template ID

Column Header

Description

Template ID

Column Header

Description

ROYALTYOBLIGATIONFACTOR

Production Date

Format YYYYMM.

ROYALTYOBLIGATIONFACTOR

Factor ID

Factor ID

  • Maximum 16 characters.

ROYALTYOBLIGATIONFACTOR

Description

Description

  • Maximum 40 characters.

Sample Data for ROYALTYOBLIGATIONFACTOR Template

Production Date

Factor ID

Description

Production Date

Factor ID

Description

201407

ACHROYRATE2

ACH ROYALTY RATE 2 update

201407

ACHPERCENTOFPROD

ACH PERCENT OF PRODUCTION

Royalty Obligation Factors After Importing - ROYALTYOBLIGATIONFACTOR

 

ROYALTYOBLIGATIONHDR

Template for ROYALTYOBLIGATIONHDR

Template ID

Column Header

Description

Template ID

Column Header

Description

ROYALTYOBLIGATIONHDR

Production Date

Format YYYYMM.

ROYALTYOBLIGATIONHDR

Well/Tract Type

Well/tract type

Options include:

  • W (Well)

  • T (Tract)

ROYALTYOBLIGATIONHDR

Well/Tract

Unique identifier for well or tract.

ROYALTYOBLIGATIONHDR

Product

Must be a valid product for Royalty Obligations.

ROYALTYOBLIGATIONHDR

Obligation Number

A four-character field that must contain only digits and typically contains several zeros (i.e., 0001).

ROYALTYOBLIGATIONHDR

Royalty Type

Indicates the type of obligation.

Options include:

  • CRWN (Crown)

  • FCLS (F-Class)

  • FRHD (Freehold)

  • IOGC (IOGC)

  • ORR (Override)

  • OTHER (Other)

ROYALTYOBLIGATIONHDR

Royalty Owner ID

Unique Identifier for Royalty Owner. 

  • Maximum 16 characters.

ROYALTYOBLIGATIONHDR

Taken In Kind

Indicates whether the Royalty Owner Takes In-Kind or not.

Options include:

  • Y (Yes)

  • N (No)

ROYALTYOBLIGATIONHDR

User Defined 1

Generic User-Defined field available to capture miscellaneous data.

  • Maximum 16 characters.

ROYALTYOBLIGATIONHDR

User Defined 2

Generic User-Defined field available to capture miscellaneous data.

  • Maximum 16 characters.

ROYALTYOBLIGATIONHDR

User Defined 3

Generic User-Defined field available to capture miscellaneous data.

  • Maximum 16 characters.

ROYALTYOBLIGATIONHDR

Note

  • Maximum 4000 characters.

 

Sample Data for ROYALTYOBLIGATIONHDR Template

By Qbyte Metrix Well ID/Tract ID:

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Royalty Type

Royalty Owner ID

Taken In Kind

User Defined 1

User Defined 2

User Defined 3

Notes

Production Date

Well/Tract Type

Well/Tract

Product

Obligation Number

Royalty Type

Royalty Owner ID

Taken In Kind

User Defined 1

User Defined 2

User Defined 3

Notes

201406

W

UNHOLB01W02

OIL

0001

FRHD

900001

Y





UD 301

Uploading Royalties

201406

W

UNHOLB01W02

GAS

0002

ORR

900002

N





UD 302



201406

W

UNHOLB01W02

BYP

0003

ORR

900003

N





UD 303



201406

T

UHOLTRACT1

OIL

0001

FRHD

900001

Y



UD T201

UD 301

Roy for Tract 1 TIK

201406

T

UHOLTRACT1

GAS

0002

ORR

900002

N



UD T202

UD 302



201406

T

UHOLTRACT1

BYP

0003

ORR

900003

N



UD T203

UD 303



201406

W

UNHOLB01W05

OIL

0001

FRHD

900001

Y

Test 4





Uploading Royalties B05

201406

T

UHOLTRACT2

OIL

0001

FRHD

900001

Y



UD T203

UD 301

Roy for Tract 2 TIK

 

Royalty Obligation After Importing - ROYALTYOBLIGATIONHDR

The Royalty Obligation will always be created with an Active Status of Pending. The Formula ID and Formula Description will be blank. A note will always be created by the process to indicate that the obligation was Imported by Template. If you had a note entered on the template for that obligation, it would be created as a second note.

Well

WELLABOILCROWN (as of Release 24.4)

Template for WELLABOILCROWN

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLABOILCROWN

Production Date

Format YYYYMM.

WELLABOILCROWN

Well

Unique identifier for a well.

WELLABOILCROWN

Oil Density

Must be greater than or equal to 0.

  • Only valid for wells in Alberta. Maximum size is 9999.99 (4v2).

WELLABOILCROWN

Crown Calculation Type

Alberta Wells only.

Options are:

  • B - Bypass

  • E - Equivalent Use

  • MRFC - MRF 2017 C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • MRFPC - MRF 2017 Post C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • N - ARF 2009 Normal

  • T - ARF 2009 Transitional

WELLABOILCROWN

Equivalent Use Sub Type

Alberta Wells only.

  • MRFC - MRF 2017 C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • MRFPC - MRF 2017 Post C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • N - ARF 2009 Normal

  • T - ARF 2009 Transitional

  • Only allowed when Crown Calculation Type is E (Equivalent Use).

 

Sample Data for WELLABOILCROWN

Production Date

Well

Oil Density

Crown Calculation Type

Equivalent Use Sub Type

Production Date

Well

Oil Density

Crown Calculation Type

Equivalent Use Sub Type

201406

01/16-20-013-05w4/0

850.00

MRFC

 

201406

01/16-19-013-05w4/0

902.00

E

MRFC

 

WELLCONSBYLABEL

Template for WELLCONSBYLABEL

Also, see the Qbyte Metrix Well Consumption Master Imports presentation that shows detailed examples of creating/importing well consumption master data.

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLCONSBYLABEL

Production Date

Format YYYYMM.

WELLCONSBYLABEL

Well 

Unique identifier for a well.

WELLCONSBYLABEL

Label of the Factor

The unique Qbyte Metrix Label assigned to the factor. This is the label column of the Gas Adjustment/Consumption Factors grid. (See below.)

WELLCONSBYLABEL

Rate

Must be greater than or equal to 0 and a maximum size of 999.99999999 (3v8).

Note: Rate is not required if Calculation Basis is INPVOL.

 

Sample Data for WELLCONSBYLABEL Template

By Qbyte Metrix Well ID:

Production Date

Well

Label of the Factor

Rate

Production Date

Well

Label of the Factor

Rate

200804

AKEIMPW01W01

FUEL12

9

200804

AKEIMPW01W01

FUEL11

8

200804

AKEIMPW01W01

FLARE1

5

200804

AKEIMPW01W01

FLARE2

6

200804

AKEIMPW01W01

FLARE3

7

200804

AKEIMPW01W01

VENT21

11

200804

AKEIMPW01W01

VENT22

12

200804

AKEIMPW01W01

GATH99

0.22

200804

AKEIMPW01W01

GATH99

0.11

200804

AKEIMPW01W01

VENT23

22

 

By UWI:

Production Date

Well

Label of the Factor

Rate

Production Date

Well

Label of the Factor

Rate

200804

01/05-24-014-06w4/0

VNT

6

200804

01/05-24-013-06w4/0

FLR

3

200804

01/05-24-012-06w4/0

VENT1

2.2

200804

01/05-24-011-06w4/0

FUL

8.5

 

Well Production After Importing - WELLCONSBYLABEL

WELLCONSDELETEBYLABEL

Template for WELLCONSDELETEBYLABEL

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLCONSDELETEBYLABEL

Production Date

Format YYYYMM.

WELLCONSDELETEBYLABEL

Well 

Unique identifier for a well.

WELLCONSDELETEBYLABEL

Label of the Factor

The unique Qbyte Metrix Label assigned to the factor.

 

Sample Data for WELLCONSDELETEBYLABEL Template

Production Date

Well

Label of the Factor

Production Date

Well

Label of the Factor

200804

AKEIMPW01W01

FUEL12

200804

AKEIMPW01W01

GATH99

200804

AKEIMPW01W01

VENT23

WELLCONSUMPTION

Template for WELLCONSUMPTION

Also, see the  Qbyte Metrix Well Consumption Master Imports presentation that shows detailed examples of creating and importing well consumption master data.

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLCONSUMPTION

Production Date

Format YYYYMM.

WELLCONSUMPTION

Well

Unique identifier for a well.

WELLCONSUMPTION

Label of the Factor

The unique Qbyte Metrix Label assigned to the factor. This is the label column of the Gas Adjustment/Consumption Factors grid. (See below.)

WELLCONSUMPTION

Calculation Basis

Indicates the basis of the factor calculation. One of the following options must be entered.

Options include:

  • GASPRD (Gas Production)

  • OILPRD (Oil Production)

  • WTRPRD (Water Production)

  • HRSPRD (Producing Hours)

  • MINPRD (Producing Minutes)

  • INPVOL (Manual Input)

  • GOR (Gas Oil Ratio)

  • STV (Stock Tank Vapour)

  • GIS (Gas In Solution)

WELLCONSUMPTION

Rate

Must be greater than or equal to 0 and a maximum size of 999.99999999 (3v8).

Note: Rate is not required if the Calculation Basis is INPVOL.

WELLCONSUMPTION

Usage Type

Used to indicate how the calculated factor volume is to be used. One of the following options must be entered.

Options include:

  • FLAR (Flared)

  • FUEL (Fuel)

  • VENT (Vented)

  • GATH (Gathered)

WELLCONSUMPTION

Adjust Production

Used to indicate whether to adjust Gas Production by calculated factor volume. One of the following options must be entered; a blank indicates Not Applicable.

Options include:

  • Y (Both Well and Battery Production adjusted)

  • N (Not adjusted)

  • W (Well Production adjusted but not Battery)

  • R (Receipt - Production not adjusted)

  • blank (Not applicable)

WELLCONSUMPTION

Recalculate on Actuals

Used to indicate whether to adjust Gas Production by calculated factor volume. One of the following options must be entered; a blank indicates Not Applicable.

Options include:

  • Y (Both Well and Battery Production adjusted)

    • N (Not adjusted)

    • W (Well Production adjusted but not Battery)

    • blank (Not applicable)

WELLCONSUMPTION

Include in Proration

Used to indicate whether the calculated factor should be included in gas proration. One of the following options must be entered; a blank indicates Not Applicable.

Options include:

  • Y (Include in Proration)

  • N (Do not include in Proration)

  • BTY (Include or not based on Battery Production options)

  • blank (Not applicable)

 

Sample Data for WELLCONSUMPTION Template

Production Date

Well

Label of the Factor

Calculation Basis

Rate

Usage Type

Adjust Production

Recalculate on Actuals

Include in Proration

Production Date

Well

Label of the Factor

Calculation Basis

Rate

Usage Type

Adjust Production

Recalculate on Actuals

Include in Proration

200804

AKEIMPW01W02

FUEL12

INPVOL

9

FUEL

N





200804

AKEIMPW01W02

FUEL11

HRSPRD

8

FUEL

N





200804

AKEIMPW01W02

FLARE1

OILPRD

5

FLARE

N

N



200804

AKEIMPW01W02

FLARE2

GASPRD

6

FLARE

N

N



200804

AKEIMPW01W02

FLARE3

MINPRD

7

FLARE

N





200804

AKEIMPW01W02

VENT21

GIS

10

VENT

Y

Y

Y

200804

AKEIMPW01W02

VENT22

STV

11

VENT

Y

Y

Y

200804

AKEIMPW01W02

GATH99

GOR

0.22

GATH

Y

N

N

200804

AKEIMPW01W02

GATH99

GOR

0.11

GATH

Y

N

N

 

Well Production After Importing - WELLCONSUMPTION

 

WELLCONSUMPTIONUPD

Template for WELLCONSUMPTIONUPD

Also, see the Qbyte Metrix Well Consumption Master Imports presentation that shows detailed examples of creating/importing well consumption master data.

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLCONSUMPTIONUPD

Production Date

Format YYYYMM.

WELLCONSUMPTIONUPD

Well

Unique identifier for a well.

WELLCONSUMPTIONUPD

Label of the Factor

The unique Qbyte Metrix Label assigned to the factor. This is the label column of the Gas Adjustment/Consumption Factors grid. (See below.)

WELLCONSUMPTIONUPD

Calculation Basis

Indicates the basis of the factor calculation. One of the following options must be entered.

Options include:

  • GASPRD (Gas Production)

  • OILPRD (Oil Production)

  • WTRPRD (Water Production)

  • HRSPRD (Producing Hours)

  • MINPRD (Producing Minutes)

  • INPVOL (Manual Input)

  • GOR (Gas Oil Ratio)

  • STV (Stock Tank Vapor)

  • GIS (Gas In Solution)

WELLCONSUMPTIONUPD

Rate

Must be greater than or equal to 0 and a maximum size of 999.99999999 (3v8).

Note: Rate is not required if the Calculation Basis is INPVOL.

WELLCONSUMPTIONUPD

Usage Type

Used to indicate how the calculated factor volume is to be used. One of the following options must be entered.

Options include

  • FLAR (Flared)

  • FUEL (Fuel)

  • VENT (Vented)

  • GATH (Gathered)

WELLCONSUMPTIONUPD

Adjust Production

Used to indicate whether to adjust Gas Production by calculated factor volume. One of the following options must be entered; a blank indicates Not Applicable.

Options include:

  • Y (Both Well and Battery Production adjusted)

  • N (Not adjusted)

  • W (Well Production adjusted but not Battery)

  • R (Receipt - Production not adjusted)

  • blank (Not applicable)

WELLCONSUMPTIONUPD

Recalculate on Actuals

Used to indicate whether the factor should be re-calculated once actual volumes are available for the Calculation Basis. One of the following options must be entered; a blank indicates Not Applicable .

Options include:

  • Y (Recalculate using actuals)

  • N (Calculate on estimates)

  • blank (Not applicable)

WELLCONSUMPTIONUPD

Include in Proration

Used to indicate whether the calculated factor should be included in gas proration. One of the following options must be entered; a blank indicates Not Applicable.

Options include:

  • Y (Include in Proration)

  • N (Do not include in Proration)

  • BTY (Include or not based on Battery Production options)

  • blank (Not applicable)

 

Sample Data for WELLCONSUMPTIONUPD

Production Date

Well

Label of the Factor

Calculation Basis

Rate

Usage Type

Adjust Production

Recalculate on Actuals

Include in Proration

Production Date

Well

Label of the Factor

Calculation Basis

Rate

Usage Type

Adjust Production

Recalculate on Actuals

Include in Proration

200804

AKEIMPW01W03

FUEL12

INPVOL

0

FUEL

N





200804

AKEIMPW01W03

FUEL11

HRSPRD

8

FUEL

N





200804

AKEIMPW01W03

FLARE1

OILPRD

5

FLAR

N

N



200804

AKEIMPW01W03

FLARE2

GASPRD

6

FLAR

N

N



200804

AKEIMPW01W03

FLARE3

MINPRD

7

FLAR

N





200804

AKEIMPW01W03

VENT21

GIS

10

VENT

Y

N

Y

200804

AKEIMPW01W03

VENT22

STV

11

VENT

Y

Y

Y

200804

AKEIMPW01W03

GATH99

GOR

0.22

GATH

Y

N

N

200804

AKEIMPW01W03

GATH99

GOR

0.11

GATH

Y

N

N

 

Well Production After Importing - WELLCONSUMPTIONUPD

 

WELLMASTERCREATION

Template for WELLMASTERCREATION

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLMASTERCREATION

Production Date

Format YYYYMM.

WELLMASTERCREATION

Well ID

Well ID

  • Maximum 16 characters.

WELLMASTERCREATION

Province

Province

Options include:

  • AB (Alberta)

  • BC (British Columbia)

  • MB (Manitoba)

  • ON (Ontario)

  • SK (Saskatchewan)

WELLMASTERCREATION

Name

The official name of the well.

  • Maximum 30 characters.

WELLMASTERCREATION

Formatted Location

Well location. The Format depends on survey system selected. (i.e., 100/01-09-025-04w4/00 or 203-A-013-K-093P01-3).

WELLMASTERCREATION

Fluid Type

Fluid type

Options include:

  • OIL (Oil)

  • GAS (Gas)

  • WATR (Water)

  • EFFL (Effluent)

WELLMASTERCREATION

Heavy Oil

Heavy oil indicator

Options include:

  • N (Non-Heavy Oil)

  • Y (Heavy Oil)

  • S (SW Saskatchewan Heavy)

WELLMASTERCREATION

Water Type

Water type

Options include:

  • H2O (Water)

  • FSHWTR (Fresh Water)

  • BRKWTR (Brackish Water)

WELLMASTERCREATION

Measurement Type

Measurement type

Options include:

  • MEAS (Measured)

  • TEST (Test-to-Test)

WELLMASTERCREATION

Well Depth

Must be greater than or equal to 0 and maximum size of 9999.9 (4v1).

WELLMASTERCREATION

Field Code

Provincial Field Code

  • Maximum 12 characters.

WELLMASTERCREATION

Pool Code

Provincial Pool Code

  • Maximum 12 characters.

WELLMASTERCREATION

Field/Pool Code

Provincial Field/Pool Code

  • Ontario Wells only.

  • Maximum 16 characters.

WELLMASTERCREATION

Government License Number

Provincial License Number Code

  • Ontario Wells only.

    • Maximum 6 digits.

WELLMASTERCREATION

Cost Centre

  • Cost Centre

    • Maximum 16 characters.

WELLMASTERCREATION

PA Responsible

  • PA Responsible

    • Must be a valid Qbyte Metrix user.

WELLMASTERCREATION

User Defined #1

Generic user-defined field available to capture miscellaneous data.

  • Maximum 16 characters.

WELLMASTERCREATION

User Defined #2

Generic user-defined field available to capture miscellaneous data.

  • Maximum 16 characters.

WELLMASTERCREATION

Report Liquid as Condensate

Options include:

  • Y (Yes)

  • N (No)

WELLMASTERCREATION

Recombined Liquid and Gas

Options include:

  • Y (Yes)

  • N (No)

WELLMASTERCREATION

Report Zero Production

Options include:

  • Y (Yes)

  • N (No)

WELLMASTERCREATION

Partner Operated Petrinex ID

Override Petrinex Id for Partner Operated Wells.

  • Maximum 30 characters.

WELLMASTERCREATION

Manitoba Well Type

Manitoba well type

Options include:

  • blank

  • D (Dummy Tract)

  • N (Non-Heavy Oil Well)

  • Z (Horizontal)

WELLMASTERCREATION

Production Status

Production status

Options include:

  • ON (On Production)

  • OFF (Off Production)

WELLMASTERCREATION

Battery

Options include:

  • blank

  • Unique identifier for the battery the well is attached to.

WELLMASTERCREATION

Note

  • Maximum 4000 characters

Sample Data for WELLMASTERCREATION Template

Production Date

Well ID

Province

Name

Formatted Location

Fluid Type

Heavy Oil

Water Type

Measurement Type

Well Depth

Field Code

Pool Code

Field/Pool Code

Government License Number

Cost Centre

PA Responsible

User Defined #1

User Defined #2

Report Liquid as Condensate

Recombined Liquid and Gas

Report Zero Production

Partner Operated Petrinex ID

Manitoba Well Type

Production Status

Battery

Note

Production Date

Well ID

Province

Name

Formatted Location

Fluid Type

Heavy Oil

Water Type

Measurement Type

Well Depth

Field Code

Pool Code

Field/Pool Code

Government License Number

Cost Centre

PA Responsible

User Defined #1

User Defined #2

Report Liquid as Condensate

Recombined Liquid and Gas

Report Zero Production

Partner Operated Petrinex ID

Manitoba Well Type

Production Status

Battery

Note

2001406

AKEABWELL01

AB

AB Template Well 1

101/05-10-013-06w4/0

EFFL

N

H2O

TEST

7200











axe0623

CODE1

CODE2

Y

N

Y

AB WI 101051001706W400



ON

TEMPAB1



201406

AKEABWELL02

AB

AB Template Well 2

101/05-10-014-06w4/0

GAS

Y

H2O

TEST

5900











axe0623





N

Y

Y

AB WI 101051001806W400



ON

TEMPAB2



201406

AKENCWELL01

BC

BC Template Well 1

201-A-006-A-006A02-5

GAS

N

H2O

TEST













axe0623





N

Y

Y

BC WI 201A015A006A025



OFF





201406

AKEBCWELL02

BC

BC Template Well 2

201-A-007-B-006A02

WATR

N

H2O

MEAS

7900











axe0623





N

Y

Y

BC WI 201A016B006A025



ON

TEMPBC2



201406

AKESKWELL01

SK

SK Template Well 1

100/05-11-015-06w3/0

OIL

Y

H2O

TEST

8000











axe0623





N

Y

Y

SK WI 100051101806W300



ON

TEMPSK1



201406

AKESKWELL02

SK

SK Template Well 2

100/05-11-016-06w3/0

OIL

S

H2O

MEAS













axe0623





N

Y

Y

SK WI 100051101906W300



ON

TEMPSK2



201406

AKEMBWELL01

MB

MB Template Well 1

100/06-12-017-01w1/1

OIL

N

H2O

TEST

9600

71245

8999







axe0623





Y

N

Y



N

ON

TEMPMB1



201406

AKEMBWELL02

MB

MB Template Well 2

100/06-12-018-01w1/1

GAS

N

H2O

MEAS

9300

71246

8999







axe0623





N

Y

Y



Z

ON

TEMPMB2



201406

AKEONWELL01

ON

ON Template Well 1

3BC-2-493-45878

OIL

Y

H2O

TEST

5500





COMBO1

328474



axe0623





N

N

Y

ON WI HG100412341



ON

TEMPON2



201406

AKEONWELL02

ON

ON Template Well 2

4493-7-49

GAS

N

H2O

MEAS

9999.1





COMBO2

328473



axe0623

CODE3

CODE4

N

N

Y

ON WI 005412



ON

TEMPON2



 

WELLMASTERGENERALUPD

Template for WELLMASTERGENERALUPD

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLMASTERGENERALUPD

Production Date

Format YYYYMM.

WELLMASTERGENERALUPD

Well

Unique identifier for a well.

WELLMASTERGENERALUPD

Formatted Location

Well Location. The Format depends on the Survey System selected. (i.e., 100/01-09-025-04w4/00 or 203-A-013-K-093P01-3).

WELLMASTERGENERALUPD

Name

The official name of the well. 

  • Maximum 30 characters.

WELLMASTERGENERALUPD

User-Defined #1

Generic user-defined field available to capture miscellaneous data.

  • Maximum 16 characters.

WELLMASTERGENERALUPD

User-Defined #2

Generic user-defined field available to capture miscellaneous data.

  • Maximum 16 characters.

WELLMASTERGENERALUPD

Field Code

Provincial Field Code

  • Maximum 12 characters.

WELLMASTERGENERALUPD

Pool Code

Provincial Pool Code

  • Maximum 12 characters.

WELLMASTERGENERALUPD

Well Depth

Must be greater than or equal to 0.

  • Maximum size is 9999.9 (4v1).

WELLMASTERGENERALUPD

Cost Centre

Cost Centre

  • Maximum 16 characters.

WELLMASTERGENERALUPD

Partner Operated Petrinex Id

Override Petrinex Id for Partner Operated Wells

  • Maximum 30 characters.

 

Sample Data for WELLMASTERGENERALUPD Template

Production Date

Well

Formatted Location

Name

User Defined #1

User Defined #2

Field Code

Pool Code

Well Depth

Cost Centre

Part.Op. Petrinex ID

Production Date

Well

Formatted Location

Name

User Defined #1

User Defined #2

Field Code

Pool Code

Well Depth

Cost Centre

Part.Op. Petrinex ID

201405

AKEIMPW01W01

 !

Changing to 888

Code 888

Code 887

Field 8

 !

8888.7

MYCOSTCENTRE888

AB WI 888

201405

AKEIMPW01W02

 !

 !

Code 777

Code 778

Field 7

777

7777.8

MyCOSTCENTRE777

 !

WELLMASTERGENERALUPDNORESET

Template for WELLMASTERGENERALUPDNORESET

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLMASTERGENERALUPDNORESET

Production Date

Format YYYYMM.

WELLMASTERGENERALUPDNORESET

Well

Unique identifier for a well.

WELLMASTERGENERALUPDNORESET

Formatted Location

Well Location

  • The Format depends on the Survey System selected. (i.e., 100/01-09-025-04w4/00 or 203-A-013-K-093P01-3).

WELLMASTERGENERALUPDNORESET

Name

The official Name of the well.

  • Maximum 30 characters.

WELLMASTERGENERALUPDNORESET

User-Defined #1

Generic user-defined field available to capture miscellaneous data.

  • Maximum 16 characters.

WELLMASTERGENERALUPDNORESET

User-Defined #2

Generic user-defined field available to capture miscellaneous data.

  • Maximum 16 characters.

WELLMASTERGENERALUPDNORESET

Field Code

Provincial Field Code

  • Maximum 12 characters.

WELLMASTERGENERALUPDNORESET

Pool Code

Provincial Pool Code

  • Maximum 12 characters.

WELLMASTERGENERALUPDNORESET

Well Depth

Must be greater than or equal to 0

  • Maximum size is 9999.9 (4v1).

WELLMASTERGENERALUPDNORESET

Cost Centre

Cost Centre

  • Maximum 16 characters.

WELLMASTERGENERALUPDNORESET

Partner Operated Petrinex Id

Override Petrinex Id for Partner Operated Wells

  • Maximum 30 characters.

Sample Data for WELLMASTERGENERALUPDNORESET Template

Production Date

Well

Formatted Location

Name

User Defined #1

User Defined #2

Field Code

Pool Code

Well Depth

Cost Centre

Part.Op. Petrinex ID

Production Date

Well

Formatted Location

Name

User Defined #1

User Defined #2

Field Code

Pool Code

Well Depth

Cost Centre

Part.Op. Petrinex ID

201405

AKEIMPW01W01

 !

Changing to 888

Code 888

Code 887

Field 8

 !

8888.7

MYCOSTCENTRE888

AB WI 888

201405

AKEIMPW01W02

 !

 !

Code 777

Code 778

Field 7

777

7777.8

MyCOSTCENTRE777

 !


 

WELLMASTERUWIUPDNORESET

Template for WELLMASTERUWIUPDNORESET

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLMASTERGENERALUPDNORESET

Production Date

Format YYYYMM.

WELLMASTERGENERALUPDNORESET

Well

Unique identifier for a well.

WELLMASTERGENERALUPDNORESET

Formatted Location

  • Well Location

The Format depends on Survey System selected (i.e., 100/01-09-025-04w4/00 or 203-A-013-K-093P01-3).

Sample Data for WELLMASTERUWIUPDNORESET Template

By Registry ID

Production Date

Well

Formatted Location

Production Date

Well

Formatted Location

200804

AB WI 0105240136w4

101/05-24-014-06w4/0

200804

BC WI A1A1102

  200-A-001-B-001102-0

 

By Qbyte Metrix Well ID:

Production Date

Well

Formatted Location

Production Date

Well

Formatted Location

201405

AKEABDESB01W01

101/05-24-014-06w4/0

201405

AKEABDESB01W02

101/05-24-013-06w4/0

201405

AKEABDESB01W03

101/05-24-012-06w4/0

201405

AKEABDESB01W04

101/05-24-011-06w4/0

201405

AKEABDESB01W05

101/05-24-016-06w4/0

201405

AKEABCONDB01W01

101/05-24-015-06w4/0

WELLPRODUCTIONFACTOR

Template for WELLPRODUCTIONFACTOR

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLPRODUCTIONFACTOR

Production Date

Format YYYYMM.

WELLPRODUCTIONFACTOR

Well

Unique identifier for a well.

WELLPRODUCTIONFACTOR

WGR Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLPRODUCTIONFACTOR

WGR Test Date

Format YYYYMMDD. Can be left blank.

WELLPRODUCTIONFACTOR

Oil Meter Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLPRODUCTIONFACTOR

EOR/HOR Rate

Saskatchewan Wells only. Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLPRODUCTIONFACTOR

Remaining Gas Option

Used to indicate how to handle any remaining gas at the Well. One of the following options must be entered.

Options include:

  • MDIF (Metering Difference)

  • FLAR (Flare)

  • FUEL (Fuel)

  • VENT (Vented)

WELLPRODUCTIONFACTOR

All Oil To Be Recovered

Options include:

  • Y (Yes)

  • N (No)

WELLPRODUCTIONFACTOR

All Water To Be Recovered

Options include:

  • Y (Yes)

  • N (No)

WELLPRODUCTIONFACTOR

Oil Gas Ratio Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLPRODUCTIONFACTOR

Oil Gas Ratio Test Date

Format YYYYMMDD. Can be left blank.

WELLPRODUCTIONFACTOR

Gas Meter Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLPRODUCTIONFACTOR

Oil Gas Ratio Code

Can be left blank.

Non-blank options include:

  • WELL (Well-level)

  • BTY (Battery-level)

WELLPRODUCTIONFACTOR

Water Gas Ratio Code

Can be left blank.

Non-blank options include:

  • WELL (Well-level)

  • BTY (Battery-level)

WELLPRODUCTIONFACTOR

 Water Meter Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLPRODUCTIONFACTOR

Battery GOR Exempt

Options include:

  • Y (Yes)

  • N (No)

WELLPRODUCTIONFACTOR

Crown Royalty Percent

Must be greater than or equal to 0 and less than or equal to 100.

  • Maximum size is 999.99999999 (3v8).

  • Sum of Crown Royalty Percent, Freehold Royalty Percent, Federal Percent, and Crown Acquired Percent must total 100.

  • Available as of Release 24.4.

WELLPRODUCTIONFACTOR

Freehold Royalty Percent

Must be greater than or equal to 0 and less than or equal to 100.

  • Maximum size is 999.99999999 (3v8).

  • Sum of Crown Royalty Percent, Freehold Royalty Percent, Federal Percent, and Crown Acquired Percent must total 100.

  • Available as of Release 24.4.

WELLPRODUCTIONFACTOR

Federal Percent

Must be greater than or equal to 0 and less than or equal to 100.

  • Maximum size is 999.99999999 (3v8).

  • Sum of Crown Royalty Percent, Freehold Royalty Percent, Federal Percent, and Crown Acquired Percent must total 100.

  • Available as of Release 24.4.

WELLPRODUCTIONFACTOR

Crown Acquired Percent

Saskatchewan Wells only. Must be greater than or equal to 0 and less than or equal to 100

  • Maximum size is 999.99999999 (3v8).

  • Sum of Crown Royalty Percent, Freehold Royalty Percent, Federal Percent, and Crown Acquired Percent must total 100.

  • Available as of Release 24.4.

WELLPRODUCTIONFACTOR

Oil Density

Must be greater than or equal to 0.

  • Only valid for wells in Alberta. Maximum size is 9999.99 (4v2).

  • Available as of Release 24.4.

WELLPRODUCTIONFACTOR

Crown Calculation Type

Alberta Wells only.

Options include:

  • B - Bypass

  • E - Equivalent Use

  • MRFC - MRF 2017 C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • MRFPC - MRF 2017 Post C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • N - ARF 2009 Normal

  • T - ARF 2009 Transitional

  • Available as of Release 24.4.

WELLPRODUCTIONFACTOR

Equivalent Use Sub Type

Alberta Wells only.

  • MRFC - MRF 2017 C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • MRFPC - MRF 2017 Post C* (only valid for dates after Alberta Modernized Royalty Framework 2017 is active)

  • N - ARF 2009 Normal

  • T - ARF 2009 Transitional

  • Only allowed when Crown Calculation Type is E (Equivalent Use).

  • Available as of Release 24.4.

 

Sample Data for WELLPRODUCTIONFACTOR

Production Date
Well
WGR Factor
WGR Test Date
Oil Meter Factor
EOR/HOR Rate
Remaining Gas Option
All Oil To Be Recovered
All Water To Be Recovered 
Oil Gas Ratio Factor
Oil Gas Ratio Test Date
Gas Meter Factor
Oil Gas Ratio Code
Water Gas Ratio Code
Water Meter Factor 
Battery GOR Exempt
Crown Royalty Percent
Freehold Royalty Percent
Federal Percent
Crown Acquired Percent
Oil Density
Crown Calculation Type
Equivalent Use Sub Type
Production Date
Well
WGR Factor
WGR Test Date
Oil Meter Factor
EOR/HOR Rate
Remaining Gas Option
All Oil To Be Recovered
All Water To Be Recovered 
Oil Gas Ratio Factor
Oil Gas Ratio Test Date
Gas Meter Factor
Oil Gas Ratio Code
Water Gas Ratio Code
Water Meter Factor 
Battery GOR Exempt
Crown Royalty Percent
Freehold Royalty Percent
Federal Percent
Crown Acquired Percent
Oil Density
Crown Calculation Type
Equivalent Use Sub Type

201406

01/16-20-013-05w4/0

0.2

20080101

0.4578



VENT

 Y













 N

100

0

0

0

850.00

MRFC

 

201406

01/16-19-013-05w3/0

0.05

20080915

0.98

0.789

MDIF

 N

 N













 N

80.5

19.5

0

0

 

 

 

 

Well Production After Importing - WELLPRODUCTIONFACTOR

WELLWGR

Template for WELLWGR

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLWGR

Production Date

Format YYYYMM.

WELLWGR

Well

Unique identifier for a well.

WELLWGR

WGR Factor

Must be greater than or equal to 0.

  • Maximum size of 999.99999999 (3v8).

WELLWGR

WGR Test Date

Format YYYYMMDD. Can be left blank.

 

Sample Data for WELLWGR

Production Date

Well

WGR Factor

WGR Test Date

Production Date

Well

WGR Factor

WGR Test Date

201406

IMPW04

4.5

20081001

201406

IMPW05

1.2

 

 

Well Production After Importing - WELLWGR

 

WELLWGROGR

Template for WELLWGROGR

Template ID

Column Header

Description

Template ID

Column Header

Description

WELLWGROGR

Production Date

Format YYYYMM.

WELLWGROGR

Well

Unique identifier for a well.

WELLWGROGR

Water Gas Ratio Code

Can be left blank.

Non-blank options include:

  • WELL (Well-level)

  • BTY (Battery-level)

WELLWGROGR

WGR Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLWGROGR

WGR Test Date

Format YYYYMMDD. Can be left blank.

WELLWGROGR

Oil Gas Ratio Code

Can be left blank.

Non-blank options include:

  • WELL (Well-level)

  • BTY (Battery-level)

WELLWGROGR

Oil Gas Ratio Factor

Must be greater than or equal to 0

  • Maximum size is 999.99999999 (3v8).

WELLWGROGR

Oil Gas Ratio Test Date

Format YYYYMMDD. Can be left blank.

Sample Data for WELLWGROGR

Production Date

Well

Water Gas Ratio Type

WGR Factor

WGR Test Date

Oil Gas Ratio Type

Oil Gas Ratio Factor

Oil Gas Ratio Test Date

Production Date

Well

Water Gas Ratio Type

WGR Factor

WGR Test Date

Oil Gas Ratio Type

Oil Gas Ratio Factor

Oil Gas Ratio Test Date

201406

AKEIMPW01W03

WELL

4.5

20081001

WELL

5.5

20140101

201406

AKEIMPW01W01

WELL

1.2



BTY





201406

AKEIMPW01W02

BTY





BTY





201406

AKEIMPW01W04

BTY





WELL

1.5

20140104

201406

AKEIMPW01W05

!

!

!

!

5.4

!

 

Well Production After Importing - WELLWGROGR

 


Copyright© 2024 IFS AB. Copying prohibited. All rights reserved.