Back to Monthly Data Entry and Balance Screens     Back to Qbyte Metrix Home

     

You can enter all battery and well data for the current month on the Battery Balance screen.

1. Click the Balance button on this screen.

2. Highlight your Battery and select the Balance option from the menu.

m1.jpg

Battery Summary

The Balance screen opens with the Summary tab. There are tabs for Well Input, Oil Balance, Gas Balance, and Water Balance.

Action buttons include:

BUTTON

DESCRIPTION

Recalculate

Runs a balance formula for all tabs.

Notes

Pops up a screen to allow you to view/maintain notes for the battery and production date.

Close

Closes the screen and returns to Schematic.

Run Process

Submits a Step process for a balanced battery.

Note: The button is disabled when the battery is closed, locked, or not balanced.

The Balanced notation at the top of the screen displays the status of the battery (Balanced or Not Balanced), including all products. If a product is Not Balanced, the battery status is also Not Balanced.

  • Batteries must be balanced before any calculations (Steps) can be initiated, i.e., Run process.

  • Battery Balance is an active screen that performs many calculations including usage-based on product production, remaining gas calculations, etc. Some of these calculations are affected by master data changes. As a result of this, each tab is deemed active, and you will be prompted to Save or Close every time you open or close it. 

Balance Checks

When the battery is Not Balanced, a Balance Checks link is displayed to the right of Not Balanced at the top left of the screen.

When the Balance Checks link is selected, all battery balance validations are executed again, and a window is displayed with the Balance Check Details.

The following visual indicators and associated descriptions provide additional information to help to identify why the battery is not balanced:

Well Input

The Well Input tab of the Battery Balance is where well level data is entered or viewed. Each well can have data inputted manually and/or loaded by the FDC process. 

When you select the Well Input tab, the Well Theoretical Summary grid will appear. The data entered here is considered theoretical until Step 1 is run for the battery. 

wellinput.png

Well Theoretical Summary 

This grid displays the following information:  


To Select Wells to Shut In or to Clear Well Production:

1. Use the Select column to select well(s) using the checkbox on the far left of the grid.

Once wells are selected, the Shut In Well and Clear Well Production buttons are enabled.

Action buttons include: 

BUTTON

DESCRIPTION

Select All

All wells in the battery will be selected.

Deselect All

All selected wells will be cleared.

Shut In Well

All selected wells will be shut in, if applicable.

Clear Well Production

The selected wells will be cleared back to No Input status.

Print Friendly

The system will open a screen with a print-friendly view of all entered data. This screen has a Print button.

2. To view well production details, select anywhere in the row of the desired well.

  • Do not use the Select box. 

  • Highlighting a well will automatically display the details for the well below the grid.

Well Production Input

If data has not been entered for the well yet, this grid will automatically add one row for data entry. The Measurement Type of this row will default to the Measurement Type from the Well Master (Test or Measured). This default can be changed by selecting the Measurement Type drop-down.

Note: If the battery is using a Calculated Battery Gas Oil Ratio, then there will be an indication in the well heading (after the Well ID), as to whether the well is Eligible or Exempt.

1. Click the Create New button to add measured and/or test rows as required.

If extra rows are created and not required, they must be deleted.

Arrow keys (Up and Down) can be used to move between rows while remaining in the same column.

Carry Forward test entries allow only the Production Hours to be entered or modified. However, the ability to change any/all fields on such a test exists if you have enabled this functionality.

The Edit Test and Modified Reason columns are related to System Generated Carry Forward test entries. The Edit Test column will include a link that will launch a pop-up that will allow you to modify any field in the test.  This will only appear when the functionality has been enabled (as per the above link).  When a System Carry Forward test has been modified with this functionality, the reason entered for the modification will appear in the Modified Reason column.

2. You can Save or Save and Advance to Next Well once all required data for a well is entered. 

Edits

Measured Wellhead Oil/Condensate

Measured Wellhead Oil/Condensate can be entered just beneath the Production grid. This is used when the well is recombining oil/condensate into the gas, but some of the oil/condensate is being measured and disposed of directly.

Measured Wellhead Oil/Condensate should not be entered unless the Well gas Recombine Liquid and Gas = Yes.  Also, it should not be entered for Effluent Wells.

Injection/Recovery (Optionally Displayed)

An Injection/Recovery section may be displayed under the Measured Wellhead Oil/Condensate field when the battery has been set up with Recovered Load Entry Method = By Well. This will allow for the entry of any unrecovered load oil or water that remains downhole at the end of the month. It is also possible (depending on setup) for the Unrecovered Load Oil/Water fields to be displayed but disabled.

Consumption Input (Optionally Displayed)

Optionally, another grid will be displayed if any consumption factors requiring monthly input have been set up in the Well Production Master.

Action buttons at the top of the Well Production Input screen include: 

BUTTON

DESCRIPTION

Save

Saves data.

Save and Advance to Next Well

Saves and moves to the next well.

Revert

Removes all unsaved data.

View Previous Entry

Opens a window showing previous monthly data.

Production History

The system opens a new window showing the wells' production history.


Factors and Consumption Detail

The Factors and Consumption Detail section is an accordion and can be toggled open or closed. This section displays the entered consumption and calculated consumption as well as oil calculated based on oil gas ratio, and water calculation based on water gas ratio or water on gas.

Summary Section

Production and Consumption Summaries appear in the Factors and Consumption Details accordion at the bottom of the screen, displaying details of all well data entered and/or calculated based on well production master settings.

Oil Balance

The battery oil movement data is entered on the Oil Balance tab. This screen will perform a production calculation and will balance the oil for the battery upon Save.

oilbalance.png

 

Receipts

You can enter new and/or update recurring oil receipts in the grid found in the Receipts area. Load oil receipts can be entered in this grid. Receipts resulting from battery-to-battery transfers and battery-to-battery injection will appear in this grid; however, not all fields will be editable as they are sourced from the disposition that created them.

receipts.png

1. Click the Create New button located below the grid.

Action buttons include Apply, Revert, and Cancel.

FIELD

DESCRIPTION

Receipt Type

Options include Deemed Sale, InjectionPrevious Month, or Transfer.

From Battery ID/Government Code/Name

Use type-ahead.

Receipt Sequence #

This field will default to 0 but can be entered by the user if there is more than one receipt of the same Receipt Type from the same Sender.

Default Well Id Outside Receipt

From System Configuration/Configuration.

To Well Id/UWI/Name

This refers to the injected well. Use type-ahead.

  • Displayed only when Receipt Type is Previous Month.

Owner Id/Name

Use type-ahead.

Volume

This field is optional.

Recovered Volume

This refers to the volume that was recovered and is only displayed when the receipt type is Injection or Previous Month

Override Receipt Code

This field is optional.

Purchased

Options include Yes or No.

  • Displayed only when the Receipt Type is Injection and the province of the facility is either Saskatchewan, Manitoba (when MB Petrinex active), British Columbia (when BC Petrinex is active), or Alberta (when Alberta Oil Valuation RTP for IOGC is active).

Report As

This field is optional. Displayed only when Receipt Type is Deemed Sale or Transfer.

Options include WCOND, COND, C2MX, C3MX, C3SP, C4MX, C4SP, C5MX, C5SP, DILUENT or SYNCRD. If left blank it will be reported as OIL.

  • Alberta, Manitoba, Saskatchewan, and British Columbia only.
    Note:

    • This is only available for Manitoba batteries when the production date is greater than or equal to MB Petrinex Implementation date.

    • This is only available for British Columbia batteries when production date is greater than or equal to BC Petrinex Implementation date.

  • See Report as Product for more information.  

User Comment

This field is optional. This functionality is especially useful when you have multiple dispositions or receipts to or from the same location. Instead of relying solely on the Delivery Sequence # to distinguish one from the other, you can add a comment that provides additional information and makes it easier to recognize the reason behind the multiples.  

Note: When there is a battery-to-battery or injection transfer, any comments entered on a disposition row of the sending facility will be auto-generated at the receiving facility, so that you do not have to re-enter the information. In these cases, the comment can only be modified at the sending facility.

2. Click Apply and return to the Receipts screen after entering the appropriate data.

3. Click Save.

The Recalculate Load Oil button will appear when the battery has Recovered Load Entry Method = By Well. This button allows you to force Qbyte Metrix to update recovered volumes on all injection/previous month receipts. Normally this is done whenever the well is saved on the Battery Balance → Well Input screen; however, since the received volume may be under the control of other batteries (when receiving load fluid from another battery) it is possible that the received volume has been updated since the unrecovered volume was entered.

Clicking the Recalculate Load Oil button forces an update to take any changes that may have occurred into account.

 

Show Fewer Columns and Show All Columns buttons:

When a battery has greater than 100 receipts, the Battery Oil Receipts grid is displayed with fewer columns. You are still able to display the grid with all of the columns by clicking the Show All Columns button.

For most batteries (i.e., with 100 receipts or less), all of the columns of the Battery Oil Receipts grid are always displayed, and you can opt to click the Show Fewer Columns button to reduce the number of columns displayed.

Showing fewer columns in the Battery Oil Receipts grid improves performance on batteries where there is a large number of receipts.

showfewer.png

Dispositions

The Dispositions area allows you to enter new and/or update recurring oil dispositions.

dispos2.png

1. Click the Create New button at the bottom of the grid.

The following fields are displayed when the Disposition Type is Delivery

FIELD

DESCRIPTION

Disposition Type

Options include Blending Shrinkage, Delivery, Fire, Injection, Spill, Theft or Transfer.

Note: Blending Shrinkage is displayed only for batteries in provinces using Petrinex (Alberta, Saskatchewan, British Columbia) for a production date greater than or equal to BC Petrinex Implementation date and Manitoba when the production date is greater than or equal to MB Petrinex Implementation date. Fire, Theft, and Spill are displayed for Saskatchewan and Manitoba (when the production date is greater than or equal to MB Petrinex Implementation date) batteries only.

Destination Facility Type

Options include Delivery System or Battery.

See Battery-to-Battery Transfers without Dependencies for more information on Destination Facility Type battery.

To Destination ID/Government Code/Name

Use type-ahead.

Delivery Sequence

This field will default to 0 but can be entered by the user if there is more than one disposition of the same Disposition Type to the same Destination.

Disposition Volume

This field is optional.

Override Delivery Code

This field is optional.

Purchased

Options include Yes or No.

  • Displayed only when the Disposition Type is Injection and the province of the facility is either Saskatchewan, Manitoba (when MB Petrinex is active), British Columbia (when BC Petrinex is active), or Alberta (when Alberta Oil Valuation RTP for IOGC is active).

Report As

Report As Product. This field is optional.

  • Displayed only when the Disposition Type is Delivery or Transfer.

Options include WCOND, COND, C2MX, C3MX, C3SP, C4MX, C4SP, C5MX, C5SP, DILUENT or SYNCRD. If left blank it will be reported as OIL.

  • Alberta, Manitoba, Saskatchewan, and British Columbia only.
    Note:

    • This is only available for Manitoba batteries when the production date is greater than or equal to MB Petrinex Implementation date.

    • This is only available for British Columbia batteries when the production date is greater than or equal to BC Petrinex Implementation date.

  • See Report as Product for more information. 

User Comment

This field is optional. This functionality is especially useful when you have multiple dispositions or receipts to or from the same location. Instead of relying solely on the Delivery Sequence # to distinguish one from the other, you can add a comment that provides additional information and makes it easier to recognize the reason behind the multiples. Comments entered appear on the Market Master to help with setting up dispositions and multiple sequences.

Note: When there is a battery-to-battery or injection transfer, any comments entered on a disposition row of the sending facility will be auto-generated at the receiving facility, so that you do not have to re-enter the information. In these cases, the comment can only be modified at the disposition facility.

2. Click Apply after entering the appropriate data.

3. Click Save.

Summary

The Summary area consists of a high-level summary of all the data elements that were previously entered. 

Gas Balance

The Gas Balance tab is where the battery gas movement data is entered including Receipts, Consumption, Dispositions, and Inventory. Upon Save, the screen will do a production calculation and balance the gas for the battery.

For Gas Flow batteries, the Gas Flow Balance button will be visible and enabled. Clicking this button will launch the Gas Flow Balance screen directly without having to back to the Explorer menu.

gasbal1.png

Receipts

Enter new and/or recurring gas receipts in the grid.

To Add a New Receipt:

1. Click the Create New button located below the grid.

Action buttons include Apply, Revert and Cancel.

FIELD

DESCRIPTION

Receipt Type

Options include Fuel ReceiptConsumption Receipt, Consumption Receipt for Wells, or Transfer for Market.

Note:

  • Consumption Receipt is used to bring in generic gas volume that will be used as consumption at either the battery or well-level.

  • Consumption Receipt for Wells is used to account for consumption received at the various wells in the battery.

    • The volume entered here must be used on wellhead consumption factors that are set up with Adjust Production = Receipt. However, wellhead consumption factors (with Adjust Production = Receipt) may also use volume from Consumption Receipt and Transfer for Consumption receipts.

Sending Entity Type

Options include Battery, Delivery System, GGS or Plant.

Sending Facility ID/Government Code/Name

Use type-ahead.

Received Volume

This field is optional.

Purchased

Options include Yes or No.

Receipt Code

This field is optional.

User Comment

This field is optional.

2. After entering the appropriate data, click Apply and return to the Receipts screen.

3. Click Save.

Consumptions

Consumption information appears in a grid format. Consumption data will appear as set up in the Battery Master. If monthly data entry is required, the Input Volume field will appear open. Gridlines showing the calculations will appear if fuel or flared is calculated. 

The action button is Allocate Volumes. Clicking the Allocate Volumes button will launch the Consumption Allocation screen, allowing you to allocate consumption to specific entities or Owners. If allocate volumes are not entered, consumption will be allocated equally to all entities flowing through this battery.

Dispositions

Enter new and/or recurring gas dispositions.

To Add a New Disposition:

1. Click the Create New button at the bottom of the grid.

FIELD

DESCRIPTION

Disposition Type

Options include Delivery, Transfer for Consumption, Transfer for Fuel or Transfer for Market.

  • If gas flow, then: Delivery, Purchased Consumption or Return Consumption for Alberta and Saskatchewan and Manitoba batteries.

  • For gas flow British Columbia batteries: Delivery, Fuel Sale, Purchased Consumption or Return Consumption.

Delivery System Type

Options include GGS, Injection or Plant

  • Battery, GGS, Plant, Injection, Delivery System.

Delivery System ID/Government Code/Name

Use type-ahead.

Metered Gas Volume

This field is optional. When populated it contains the volume of disposed gas.

Metered Liquid Volume

This field is optional. When populated it contains the volume of disposed liquid.

Gas Equivalent Factor

This field is optional. It will be enabled only when there is not a battery analysis entered. When populated it contains the GEQ factor to be used to convert the Metered Liquid Volume to gas.

Total Volume

This is a display-only field that will show the sum of the Metered Gas Volume and the gas equivalent of the Metered Liquid Volume

Purchased

Options include Yes or No. The field is disabled for disposition types Purchased Consumption, Return Consumption and Fuel Sale.

  • This field defaults to Yes for Purchased Consumption and Fuel Sale, and defaults to No for Return Consumption. 

Delivery Code

This field is optional.

User Comment

This field is optional.

2. Click Apply and return to the Disposition screen after entering the appropriate data.

3. Click Save.

Theoretical Summary

The last section is the Theoretical Summary section. This section is a high-level summary of all the data elements entered previously.

Water Balance

The Water Balance tab is where the battery water movement data is entered. Upon Save, the screen will perform a production calculation and will balance the water for the battery.

waterbal.png

Receipts

You can enter new and/or update recurring oil receipts in the grid found in the Receipts area. Load water receipts can be entered into this grid. Receipts resulting from battery-to-battery transfers and battery-to-battery injection will appear in this grid; however, not all fields will be editable as they are sourced from the disposition that created them.

receipts1a.png


To Add a New Receipt:

1. Click the Create New button located below the grid.

createwaterreceipt.png

Action buttons include Apply, Revert, and Cancel.

FIELD

DESCRIPTION

Receipt Type

Options include Deemed SaleInjectionPrevious Month, or Transfer.

Sending Facility Type

Options include Battery, Delivery System, GGS, or Injection.

Sending Facility ID/Government Code/Name

Use type-ahead to populate this field.

Sequence Number

This field will default to 0 but can be entered by the user if there is more than one disposition of the same Receipt Type from the same Sender.

Received Volume

This field is optional.

Receipt Code

This field is optional.

Report As

Report As Product. This field is optional. Options include FSHWTR, BRKWTR, or STEAM. If left blank it will be reported as WATER.

  • Alberta, Manitoba, Saskatchewan, and British Columbia only.
    Note:

    • This is only available for Manitoba batteries when the production date is greater than or equal to MB Petrinex Implementation date.

    • This is only available for British Columbia batteries when the production date is greater than or equal to BC Petrinex Implementation date.

  • See Report as Product for more information. 

User Comment

This field is optional. This functionality is especially useful when you have multiple receipts from the same location. Instead of relying solely on the Sequence # to distinguish one from the other, you can add a comment that provides additional information and makes it easier to recognize the reason behind the multiples.  

Note: When there is a battery-to-battery or injection transfer, any comments entered on a disposition row of the sending facility will be auto-generated at the receiving facility, so that you do not have to re-enter the information. In these cases, the comment can only be modified at the sending facility.

2. Click Apply to return to the Receipts screen after entering the appropriate data.

3. Click Save.

The Recalculate Load Water button will appear when the battery has Recovered Load Entry Method = By Well. This button forces Qbyte Metrix to update recovered volumes on all injection/previous month receipts. Normally, this is done whenever the well is saved on the Battery Balance → Well Input screen; however, since the received volume may be under the control of other batteries (when receiving load fluid from another battery), it is possible that the received volume has been updated since the unrecovered volume was entered.

By clicking the Recalculate Load Water button, you force the update to take any changes that may have occurred into account.

Show Fewer Columns and Show All Columns buttons:

When a battery has greater than 100 receipts, the Battery Water Receipts grid is displayed with fewer columns. You are still able to display the grid with all of the columns by clicking the Show All Columns button.

For most batteries (i.e., with 100 receipts or less), all of the columns of the Battery Water Receipts grid are always displayed, and you can click the Show Fewer Columns button to reduce the number of columns displayed.

Showing fewer columns in the Battery Water Receipts grid improves performance on batteries where there is a large number of receipts.

rc1.png

Dispositions

Enter new and/or update recurring dispositions.


To Add a New Disposition: 

1. Click the Create New button at the bottom of the grid.

Action buttons include Apply, Revert, and Cancel.

FIELD

DESCRIPTION

Disposition Type

Options include Delivery, Injection, Transfer, or Spill.

Note:  Spill is displayed for Saskatchewan and Manitoba (when production date is greater than or equal to MB Petrinex Implementation date) batteries only .

Destination Facility Type

Options include Battery, Delivery System, or Injection.

To Destination ID/Government Code/Name

Use type-ahead to populate this field.

Sequence Number

This field will default to 0 but can be entered by the user if there is more than one disposition of the same Disposition Type to the same Destination.

Volume

This field is optional.

Delivery Rec Code

This field is optional.

Report As

Report As Product. This field is optional.

Options include FSHWTR, BRKWTR, or STEAM. If left blank it will be reported as WATER.

  • Alberta, Manitoba, Saskatchewan, and British Columbia only.
    Note:

    • This is only available for Manitoba batteries when the production date is greater than or equal to MB Petrinex Implementation date.

    • This is only available for British Columbia batteries when the production date is greater than or equal to BC Petrinex Implementation date.

  • See Report as Product for more information. 

User Comment

This field is optional. This functionality is especially useful when you have multiple dispositions to the same location. Instead of relying solely on the Sequence # to distinguish one from the other, you can add a comment that provides additional information and makes it easier to recognize the reason behind the multiples.

Note: When there is a battery-to-battery or injection transfer, any comments entered on a disposition row of the sending facility will be auto-generated at the receiving facility, so that you do not have to re-enter the information. In these cases, the comment can only be modified at the disposition facility.

2. Click Apply and return to the Receipts screen after entering the appropriate data.

3. Click Save.

Summary

The last section is the Summary section. This is a high-level summary of all the data elements entered previously.